2 burner and nozzle characteristics table, 3 arrangement of the burners on the hob, Instructions for the installer – Smeg CE6GPXU User Manual
Page 29

Instructions for the installer
61
16.2 Burner and nozzle characteristics table
Burner
Rated heating
capacity (kW)
LPG – G30/G31 28/37 mbar
Nozzle
diameter 1/
100 mm
By-pass
1/100
mm
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1.0
50
30
400
73
71
Semi rapid
1.8
65
33
500
127
125
Triple crown
4.0
100
65
1600
290
286
The nozzles and data concerning TOWN GAS are available at the Authorised Service Centres.
Burner
Rated heating
capacity (kW)
NATURAL GAS – G20/G25 20/25 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary
1.0
72 (X)
400
Semi rapid
1.8
97 (Z)
500
Triple crown
4.0
135 (K)
1600
16.3 Arrangement of the burners on the hob
BURNERS
1. Auxiliary
2. Semi rapid
4. Triple crown
min. and max. Ø (in cm)
12 - 14
16 - 24
18 - 26
See also other documents in the category Smeg Kiln:
- S2010MF1 (22 pages)
- SIL290X (24 pages)
- SE1055MFX (24 pages)
- ALFA201XE (17 pages)
- ALFA31DA (19 pages)
- F166-5 (28 pages)
- WIL61BVM (24 pages)
- KE455X (27 pages)
- FC66B1 (30 pages)
- AP320EB (23 pages)
- ALFA41XE (16 pages)
- SE598XGT (23 pages)
- 910TB124 (25 pages)
- SC321X (20 pages)
- ALFA41VEK (18 pages)
- SCP111NE1 (38 pages)
- A31X-6 (40 pages)
- FP130B (27 pages)
- ALFA200X (14 pages)
- SE995XT-7 (30 pages)
- CE6IPX (29 pages)
- Electric Multifunction F170K-5 (21 pages)
- APL360XC1 (27 pages)
- SA702X-5 (28 pages)
- SA301W-5 (28 pages)
- A1-6 (31 pages)
- FOVP (16 pages)
- AP361MFX (27 pages)
- SC106ALU (29 pages)
- OF902XA (16 pages)
- FP131B1 (30 pages)
- SCP111NU2 (28 pages)
- ALFA135BV (16 pages)
- CE92GPX (31 pages)
- SCP111-2 (34 pages)
- SC166PZ (29 pages)
- ALFA135V6 (17 pages)
- CE92IPX (30 pages)
- ALFA141VE (17 pages)
- SA301X (20 pages)
- SCDK398X (26 pages)
- A42C (29 pages)
- XXSC111P (32 pages)
- CE9IMX (27 pages)