beautypg.com

To verify attached storage (for the solaris os) – Sun Microsystems SG-XPCIE1FC-EM8-Z User Manual

Page 46

background image

20

Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008

▼ To Verify Attached Storage (for the Solaris OS)

If online storage is connected to the HBA, use the apply show-children
command to list the attached storage.

assigned-addresses 82080110 00000000 03504000 00000000

00002000

82080118 00000000 03506000 00000000 00002000

81080120 00000000 00003100 00000000 00000100

82080130 00000000 03580000 00000000 00040000

port_wwn 10 00 00 00 c9 4b 3b 39

node_wwn 20 00 00 00 c9 4b 3b 39

alternate-reg

01080120 00000000 00000000 00000000 00000100

reg

00080100 00000000 00000000 00000000 00000000

03080110 00000000 00000000 00000000 00001000

03080118 00000000 00000000 00000000 00000100

02080130 00000000 00000000 00000000 00020000

compatible pci10df,fc20

clock-frequency 02625a00

#size-cells 00000000

#address-cells 00000002

copyright Copyright (c) 2008 Emulex

model LPe12002-S

name SUNW,emlxs

device_type scsi-fcp

manufacturer Emulex

fcode-version 1.50a8

fcode-rom-offset 0000c000

devsel-speed 00000000

class-code 000c0400

interrupts 00000002

latency-timer 00000000

cache-line-size 00000010

max-latency 00000000

min-grant 00000000

subsystem-id 0000fc22

subsystem-vendor-id 000010df

revision-id 00000002

device-id 0000fc20

vendor-id 000010df

{0} ok

This manual is related to the following products: