14
MODEL
WA-6011S
WA-8011S
WA-1011S
WA-1211S
Energy Star
Cooling (BTU)
6000
8000
10000
12000
Dehumidify (pints/hr)
1.3
1.7
2.7
3.2
EER (BTU/H.W.)
10.7
10.8
10.8
10.8
Power Input
115V~, 60Hz
115V~, 60Hz
115V~, 60Hz
115V~, 60Hz
Amps
5.4
7
8.8
10.2
Watts
560
740
930
1110
Power Cord Length
6 ft
6 ft
6 ft
6 ft
NEMA Plug Type
LCDI 5-15P, 10A
LCDI 5-15P, 13A
LCDI 5-15P, 15A
LCDI 5-15P, 15A
Unit Dimension
(W x H x D) in.
16.25 x 12.31 x 15.75
19.13 x 12.8 x 15.75
19.69 x 14.75 x 20.94
19.69 x 14.75 x 20.94
Packing Dimension
(W x H x D) in.
18 x 14.5 x 17
22 x 14.5 x 18
22 x 17 x 23
22 x 17 x 23
Net/Gross Weight (lbs)
40/45
46/55
58.5/65
68/75
Window Width
(Min / Max)
23 / 36 in.
23 / 36 in.
23 / 36 in.
23 / 36 in.
Window Height (Min)
13 in.
14 in.
14.25 in.
14.25 in.
Refrigeration
R410A
R410A
R410A
R410A
Air Flow M3/H(CFM)
250
380
500
500
Noise (dB)
55.6/53.4/51.3
60.5/57.3/53.2
59.3/56.1/51.4
58.9/55.7/51.2
Fan Speeds
3
3
3
3
Dry Modes
Auto Mode
Energy Saver
Sleep Mode
Auto Restart
Filter Check
250 hours
250 hours
250 hours
250 hours
24hr On/Off Timer
Directional Louver
Left-Right
Left-Right / Up-Down
Left-Right / Up-Down
Left-Right / Up-Down
Filter Access
Slide-out
Tilt-out
Tilt-out
Tilt-out
SPECIFICATIONS
Water dripping
OUTSIDE when unit is
cooling
Remote sensing
deactivating
prematurely (some
models)
Room too cold
Unit removing large quantity of moisture from humid room. This is normal during
excessively humid days.
Set temperature too low, increase set temperature.
Remote control not used within range. Place remote control within 20 feet and 180°
radius to the front of the unit.
Remote control signal obstructed. Remove obstruction