Electrical, Electrical box contents, Fuses 4a transformer lcp-tbs – Southbend 6" x 18" SURFACE GRINDER SB1029 User Manual
Page 55: Ref part # description ref part # description, 440v conversion kit

For Machines Mfg. Since 8/09
Model SB1029
-53-
P A R T S
AMP
THERMAL
RELAY
CONTACTOR
Allen Bradley
C09400
1
3
5
7
L1
L2
L3
L4
2
4
6
8
T1
T2
T3
T4
95
96
NO
NC
97
98
AMP
THERMAL
RELAY
CONTACTOR
Allen Bradley
C09400
1
3
5
7
L1
L2
L3
L4
2
4
6
8
T1
T2
T3
T4
95
96
2.4
1.6
0.25
0.1
0.32
NO
NC
97
98
1
2
3
4
5
1
2
3
4
5
T
S
R
U1
W
V
U
0
7
6
4
3
2
R1
T1
1
GND
Fuses
4A
Transformer LCP-TBS
0 12 24 0 110
0 208 220 440 480
Electrical
Box Contents
W1
V1
U1
AB 193 TAB60
AMP
THERMAL
RELAY
440V CONVERSION KIT
95
96
2.4
1.6
NO
NC
97
98
AB 193 TAB60
AB 193 TAB24
501
502
503
504
510
505
506
507
508
509
AMP
THERMAL
RELAY
95
96
NO
NC
97
98
0.25
0.1
0.32
AB 193 TAB24
REF PART #
DESCRIPTION
REF
PART #
DESCRIPTION
501
PSB1029501
TRANSFORMER LCP-TBS 0–480V
506
PSB1029506
FUSE HOLDER
502
PSB1029502
CONTACTOR AB C09400 24V
507
PSB1029507
FUSE 4A
503
PSB1029502
CONTACTOR AB C09400 24V
508
PSB1029508
TERMINAL BLOCK 18P
504
PSB1029504
THERMAL RELAY AB 193 TAB60 1.6–2.4A
509
PSB1029509
GROUNDING BLOCK
505
PSB1029505
THERMAL RELAY AB 193 TAB24 0.1–0.32A
510
PSB1029510
440V CONVERSION KIT FOR SB1029
Electrical