beautypg.com

0 error conditions/error messages, 1 summer logic, 2 overheat condition – Sundance Spas CONSTANCE 6530-512X User Manual

Page 48: 3 panel displays sn1

background image

Page 44

ELITE SERIES

13.0 Error Conditions/Error Messages

There are a number of unique functions designed into your spa to protect

it from damage and/or aid in troubleshooting. Refer to Sections 13.1-13.8

below for a listing of all possible error messages and their meanings.

13.1 Summer Logic

When the actual spa water temperature reaches up to 2°F

(1°C) above the set temperature, the spa goes into

“summer logic”. The circulation pump will turn off

automatically, if running, to avoid adding additional heat

to the water, eventually creating an overheat condition. This

setting is not user-programmable.

Note: The summer logic does not take effect until the spa water

temperature reaches 95°F (35°C). This condition is more likely in

excessively hot weather. Remember, the spa’s ability to cool is directly

affected by the ambient temperature. An excessively hot ambient

temperature may prevent the spa from cooling down because it’s

fully insulated construction is designed to retain heat and to minimize

operating costs.

13.2 Overheat Condition

WARNING: RISK OF HYPERTHERMIA (OvER-HEATING)

CAUSING SEvERE INjURY, bURNS, OR WELTS.

!

dO NOT ENTER SPA WATER! Water is too hot. Overheat

protection. Heater is deactivated. Spa water temperature

is above acceptable limits.

When the actual water

temperature is approximately 2°F (1°C) above the set temperature, the

circulation pump will stop operating to reduce (frictional) heating. To

correct condition, remove spa cover to speed cooling.

(CAUTION! Never

leave spa uncovered when children are present!) If condition persists,

contact your authorized Sundance dealer.

13.3 Panel displays SN1

Open sensor (heater is disabled) or shorted sensor (spa is

deactivated). The high-limit temperature sensor is not

functioning. Your authorized dealer must repair this.