beautypg.com

Rs-232c port specifications – Sharp Aquos LC 32G4U User Manual

Page 96

background image

96

RS-232C port specifications

Return code

Command 4-digits

Parameter 4-digits

PC Control of the System

• When a program is set, the Display can be controlled from the PC using the RS-232C terminal.

The input signal (PC/AV) can be selected, the volume can be adjusted and various other adjustments and
settings can be made, enabling automatic programmed playing.

Attach an RS-232C cable cross-type (commercially available) to the supplied Din/D-Sub RS-232C for the

connections.

NOTE

• This operation system should be used by a person who is accustomed to using computers.

Communication conditions
Set the RS-232C communications settings on the PC to match the display’s communications conditions.
The Display’s communications settings are as follows:

Baud rate:

Parity bit:

Data length:

Stop bit:

Flow control:

9,600 bps

8 bits
None

1 bit

None

Appendix

Command format

Communication procedure
Send the control commands from the PC via the RS-232C connector.
The display operates according to the received command and sends a response message to the PC.
Do not send multiple commands at the same time. Wait until the PC receives the OK response before sending
the next command.

Eight ASCII codes e CR

Command 4-digits:Command. The text of four characters.
Parameter 4-digits:Parameter 0 – 9, x, blank, ?

Parameter

Input the parameter values, aligning left, and fill with blank(s) for the remainder. (Be sure that 4 values are input for the
parameter.)
When the input parameter is not within an adjustable range, “ERR” returns. (Refer to “Response code format”.)
No problem to input any numerical value for “x” on the table.

When “?” is input for some commands, the present setting value responds.

C1 C2 C3 C4 P1 P2 P3 P4

0

0

5

5

1

0

0

Ϫ

3

0

0

0

0

9

0

?

?

?

?

?

This manual is related to the following products: