10.2 Burner and nozzle characteristics table

Burner

R

ATED

HEATING

CAPACITY

(

K

W)

LIQUID GAS – G30/G31 30/37 mbar

Nozzle

diameter

1/100 mm

By-pass

1/100 mm

Reduced

capacity

(W)

Capacity

g/h G30

Capacity

g/h G31

Auxiliary (1)

1.05

50

28 *

30 **

350

76

75

Semi-rapid (2)

1.75

65

32 *

33 **

450

127

125

Rapid (3)

2.3

75

42 *

45 **

800

167

164

Ultra-rapid (4)

3.5

94

63 *

65 **

1500

254

250

Ultra-rapid (5)

3.9

100

63 *

65 **

1500

284

278

Fish burner (6)

1.9

68

42 *

45 **

900

138

136

*/**: the diameters market with * and ** must be respectively fitted onto the taps
marked with * and ** seen in the paragraph"11.1 Adjusting the minimum for city and
natural gas".

Burner

R

ATED

HEATING

CAPACITY

(

K

W)

METHANE GAS – G20 20 mbar

Nozzle diameter 1/100

mm

Reduced capacity (W)

Auxiliary (1)

1.05

72

350

Semi-rapid (2)

1.75

97

450

Rapid (3)

2.5

108

800

Ultra-rapid (4)

3.5

133

1500

Ultra-rapid (5)

3.9

135

1500

Fish burner (6)

1.9

94

900

Burner

R

ATED

HEATING

CAPACITY

(

K

W)

CITY GAS – G110 8 mbar

Nozzle diameter 1/100

mm

Reduced capacity (W)

Auxiliary (1)

1.05

145

350

Semi-rapid (2)

1.75

185

450

Rapid (3)

2.5

230

800

Ultra-rapid (4)

3.5

290

1500

Ultra-rapid (5)

3.8

350

1500

Fish burner (6)

1.9

190

900

To identify the burners on your hob, refer to the drawings in point "4. GET