beautypg.com

Sanyo CL2472 User Manual

Page 47

background image

Since the indications cover various units, the corresponding parts listed below may not be present in some models.

REMOTE CONTROL receiver

(1) OPERATION lamp

(2) TIMER lamp

(3) QUIET lamp

ION lamp

OPERATION button

INDOOR UNIT

(1) Self-diagnostics Lamps

Indication on indoor unit

.... OFF

Timer

Operation

Code

Diagnostics items

Diagnostics contents

S01

Room temperature sensor failure

Indoor heat exchanger sensor failure

Humidity sensor failure

Compressor temperature sensor failure

Outdoor heat exchanger sensor failure

Outdoor air temperature sensor failure

Indoor/outdoor communications failure

(serial communications)

Outdoor unit external ROM (OTP data)

failure

Peak current cut-off

• HIC circuit failure

• Power Tr (transistor) circuit failure

PAM circuit failure

Active circuit failure

Outdoor system communications failure

OLR operation

Outdoor power supply open phase

Outdoor coil freezing

Compressor discharge overheat

prevention activated.

Indoor fan operating failure

No-refrigerant protection

DC compressor drive circuit failure

Outdoor fan operating failure

Freeze-prevention operation activated.

4-way valve switching failure

Indoor zero-cross failure

Outdoor electrical current detection

failure

S02
S03

S04

S05

S06
S07

E01

E02

E03
E04
E05

E06

E07

E08
E09
E10

E11

E12

E13

.... Blinking

.... ON (Illuminated)

Quiet

(3)

(2)

(1)

(1) Sensor open circuit or short circuit

(2) Contact failure at connector or open circuit at terminal crimping location

(short-circuit detection only for the humidity sensor)

(3) Indoor/outdoor PCboard failure

(1) Sensor open circuit or short circuit

(2) Contact failure at connector or open circuit at terminal crimping location

(3) Outdoor PCboard failure

Outdoor PCboard failure

(1) Mis-wiring (2) AC power failure (3) Blown fuse (4) Power Relay failure

(5) Indoor or outdoor PCboard failure (6) Outdoor Fan Motor failure (7) Reactor failure

(8) High-Pressure Switch failure (9) Overload Relay failure (10) Magnetic Coil failure

* See detailed flowchart in this section.
(1) HIC or power Tr failure (2) Outdoor fan does not turn. (3) Instantaneous power outage

(4) Service valve not opened. (5) Outdoor fan blocked. (6) Continuous overload operation

(7) Compressor failure (8) Outdoor PCboard failure

(1) External ROM data failure (2) Outdoor PCboard failure
(1) Instantaneous power outage (2) HIC or power transistor failure

(3) Outdoor PCboard failure
(1) Outdoor PCboard failure (2) Outdoor power supply voltage failure

(1) Electric expansion valve failure (2) Capillaries choked (3) Shortage of refrigerant

(4) Continuous overload operation (5) Outdoor fan does not rotate (6) Outdoor PCboard failure

(1) Fan motor failure (2) Contact failure at connector (3) Indoor PCboard failure

(1) 4-way valve failure (heat pump model only)

(2) Outdoor PCboard failure
(1) Service valve not opened. (2) Shortage of refrigerant

(1) Open phase (2) Outdoor PCboard failure

(1) Fan motor failure (2) Contact failure at connector (3) Outdoor PCboard failure

(1) Mis-wiring (2) Blown fuse (3) Power Relay failure (4) Outdoor PCboard failure

(5) Compressor failure

* See detailed flowchart in this section.

(1) Indoor fan system failure (2) Shortage of refrigerant (3) Low-temperature operation

47

This manual is related to the following products: