beautypg.com

Sanyo CL2472 User Manual

Page 11

background image

Indoor Unit

KS1872

Outdoor Unit CL1872

< 208V >

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Remarks: Rating conditions are:

Cooling: Indoor air temperature 80°F D.B. / 67°F W.B.

Outdoor air temperature 95°F D.B. / 75°F W.B.

Vertical

dB-A

dB-A

Indoor : Hi/Me/Lo/Qt*

Outdoor : Hi

Air Filter

Compressor

Refrigerant / Amount charged at shipment

Ibs (g)

Refrigerant Control

7.7

1,500

( 1.2 to 7.7 )

( 250 to 1,500 )

17,500

5.15

( 4,000 to 17,500 )

( 1.2 to 5.15 )

Shipping Volume

Cooling

13,100

4,400

Net

Shipping

Package Dimensions

Weight

Height × Width × Depth

Height × Width × Depth

Ibs (kg)

Ibs (kg)

cu.ft (m

3

)

(mm)

inch

(mm)

208V Single-Phase 60Hz

inch

187 to 253

Dimensions

&

Weight

(*Qt = Quiet mode)

Refrigerant Tubing Connections

Unit Dimensions

Operation Sound

Electrical

Rating

Sensible Capacity

Latent Capacity

W

Power Input

V

A

Available Voltage Range

Running Amperes

Refrigerant Tube Kit / Accessories

Narrow tube

Wide tube

Refrigerant

inch (mm)

Tube Diameter

inch (mm)

26.5

33.1

4.23

(12.0)

(15.0)

(0.12)

90.4

99.2

9.88

(41.0)

(45.0)

(0.28)

29-1/8 Ч 39-27/32 Ч 14-31/32

(740 Ч 1,012 Ч 380)

(298 Ч 1,065 Ч 218)

(670 Ч 880 Ч 285)

11-3/8 Ч 44-7/8 Ч 14-29/32

(289 Ч 1,140 Ч 379)

Outdoor Unit

Indoor Unit

11-23/32 Ч 41-15/16 Ч 8-19/32 26-3/8 Ч 34-21/32 Ч 11-7/32

1/4 (6.35)

1/2 (12.7)

ft (m)

Max. allowable tubing length at shipment

Flare Type

25 (7.5)

42 / 38 / 30 / 28

51

R410A / 2.87 (1,300)

Electric Expansion Valve

Washable, Anti-Mold

DC Twin Rotary (Inverter)

Manual

Auto

Timer

Indoor / Outdoor

Fan Speeds

24-Hour ON or OFF Timer, 1-Hour OFF Timer

Auto and 3 steps / Auto (Hi and multi steps)

Airflow Direction (Indoor)

Horizontal

Controls / Temperature Control

Control Unit

Microprocessor / I.C. Thermister

Wireless Remote Control Unit

Features

Compressor Locked Rotor Amperes

Optional / Air Clean Filter

BTU/h

Performance

%

Power Factor

94

A

17.5

Voltage Rating

BTU/h

kW

Total Capacity

BTU/h

SEER

BTU/Wh

20

524 (890)

Air Circulation (High)

ft

3

/min (m

3

/h)

4.89

Moisture Removal (High)

Pints/h

EER

BTU/h/W

11.7

Fuse or Circuit Breaker Capacity

A

20

11

This manual is related to the following products: