PC/TS Adapter

Quick Reference Guide

PC/TS Adapter
A5E00078070-02

13

6.4

Connection Procedures

Switch PC/
modem off

Establish cable
connection on
RS232 side of
the adapter

(see 6.2 “General”, RS232 side)

Connect MPI/DP
connector of
adapter to
S7/M7/C7 system

(See 6.2 “General”, MPI/DP side)
=> Microprocessor in adapter starts
to work and switches the Power
LED to constant light after blinking
three times (see also 6.6 “Function
of the Power LED”)

Switch PC/
modem on

1st startup?

Start

N

Y

Start “Set PG/PC
interface”

Adapter installieren

Can be done on installing the
STEP 7 Standard Package. If so,
check settings now.

Parameter-
ize interface

N

Start PG/PC ->
MPI/DP network
communication

End

Close “Set PG/PC
interface”

Install adapter

TS adapter?

Check
“parameterization”
with TS application

Y

Parameterization resident in the TS adapter.
Reparameterization is possible in direct
connection and in modem connection.

LED “Active” indicates that the adapter is
active in the MPI/DP network.