0 typical hot tub wiring diagrams a-b, North american 60 hz models only), Danger – Sundance Spas ALTAMAR 880 User Manual

Page 75

background image

Page 69

880 SERIES

Red (L2)

Pigtail

Neutral Bus

Ground

TB2

TB1

Black (L1)

Green

Main

Service

Panel

with

GFCI

2-Pole

GFCI

Breaker

Ground/Bonding Lug**

2-Pole Circuit Breaker with 2-Wire Grounded Load Connection

(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)

White (N)

Black (L1)

Red (L2)

240 VAC

No Load Neutral Wire

Note: service disconnect not
shown in this diagram.
The control box TB1 terminal
position varies between models.

B

R

Red (L2)

Red (L2)

Pigtail

Neutral Bus

Ground

TB2

Black (L1)

Black (L1)

Green

GFCI Sub Panel*

Main Panel*

2-Pole

GFCI

Breaker

Ground/Bonding Lug**

No Load Neutral Wire

Main Panel with Secondary GFCI Shut-Off Box Using a

2-Pole GFCI Breaker with 2-Wire Grounded Connection

(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)

TB1

White (N)

Green (Ground)

*GFCI Sub Panel commonly
used when recommended GFCI
does not install in Main Panel.

Note: service disconnect not
shown in this diagram.
The control box TB1 terminal
position varies between models.

B

R

B

A

SENTR

Y

SPA CONROLLER

SENTR

Y

SPA CONROLLER

240 VAC

DANGER

Turn power off
before servicing. This
task should only be
performed by a quali-
fied technician.

!

RISK OF SHOCK OR
ELECTROCUTION!

21.0 Typical Hot Tub Wiring diagrams A-B (North Ameri-

can 60 Hz Models Only)