Sundance Spas ALTAMAR 880 User Manual
Page 14
Page 8
880 SERIES
3.3
important Additional CSA Safety instructions (Canada Only)
When using this electrical equipment, basic safety precautions should
always be followed, including the following:
1.
reAd ANd FOLLOW ALL iNSTrUCTiONS.
2. A green colored terminal or a terminal marked G, Gr, Ground,
Grounding or the symbol* is located inside the supply termi-
nal box or compartment. To reduce the risk of electric shock, this
terminal must be connected to the grounding means provided in the
electric supply service panel with a continuous copper wire equiva-
lent in size to the circuit conductors that supply this equipment (*IEC
Publication 417, Symbol 5019).
3. At least two lugs marked “Bonding Lugs” are provided on the exter-
nal surface or on the inside of the supply terminal box/compartment.
To reduce the risk of electric shock, connect the local common bond-
ing grid in the area of the spa to these terminals with an insulated or
bare copper conductor not smaller than No. 6 AWG (10 mm²).
4. All field installed metal components such as rails, ladders, drains or
other similar hardware within 10 feet (3m) of the spa shall be bonded
to the equipment grounding buss with copper conductors not smaller
than No. 6 AWG (10 mm²).
5.
SAVe THeSe iNSTrUCTiONS.