Sundance Spas ALTAMAR 880 User Manual
Page 55
Page 49
880 SERIES
Summer Logic: In warm weather, the water temperature in the hot
tub may exceed the set temperature. This condition may occur due
to heat transference from the filter/circulation pump and jets pumps.
If the water temperature is higher than 95°F (35°C) and rises two
degrees above the set temperature, a “Summer Logic” condition
occurs that deactivates the filter/circulation pump and ozonator (if
equipped). This safety feature cannot be altered! The filter/circula-
tion pump and ozonator will remain off until the water temperature
cools to the set temperature (except between 9am-11am when the
filter/circulation pump runs for it’s mandatory 2 hour cycle.)
Note: Pressing the select button at this time will reactivate the
circulation pump and waterfall feature for 1 hour. To help prevent
a “Summer Logic” condition, it may be necessary to reduce filter/
circulation pump cycles run times in warm weather.
Press the
(MOde)
button to select “Economy” mode. To make
adjustments, first press the
(CYCLe)
button to enter the filter cycle
programming mode. The LCD screen will display the following in the
upper right corner:
This means the system is ready to accept you changes to the start time
for cycle number one. Simultaneously, the large four-digit display in the
center of the screen displays the currently programmed start time for that
cycle. At this point, you have four options. You may:
1. Press
(UP)
or
(dOWN)
button to adjust the start time in
increments of 30 minutes.
2. Press
(CYCLe)
button to display and adjust each subsequent
cycles start time. With each press, the currently programmed status
will be shown in the large four digit display. To adjust any displayed
value, simply press the
(UP)
or (dOWN)
button.
3. Press
(SeLeCT)
button to move down the menu from Start
Time to Duration, with each press, the currently programmed
duration will be shown in the large four-digit display. Press
(UP)
or (dOWN)
button to adjust the duration in increments
of 15 minutes.
4. Press
(diSPLAY)
button to save changes and recall the main
water temperature display.
Note: If no button is pressed within 30 seconds, all changes are
recorded and the screen automatically returns to the standard water
temperature display.
*Note: Number will vary
according to which filter
cycle is being programmed.
1*