880 SERIES

Summer Logic: In warm weather, the water temperature in the hot

tub may exceed the set temperature. This condition may occur due

to heat transference from the filter/circulation pump and jets pumps.

If the water temperature is higher than 95°F (35°C) and rises two

degrees above the set temperature, a “Summer Logic” condition

occurs that deactivates the filter/circulation pump and ozonator (if

equipped). This safety feature cannot be altered! The filter/circula-

tion pump and ozonator will remain off until the water temperature

cools to the set temperature (except between 9am-11am when the

filter/circulation pump runs for it’s mandatory 2 hour cycle.)

Note: Pressing the select button at this time will reactivate the

circulation pump and waterfall feature for 1 hour. To help prevent

a “Summer Logic” condition, it may be necessary to reduce filter/

circulation pump cycles run times in warm weather.

Press the

(MOde)

button to select “Economy” mode. To make

adjustments, first press the

(CYCLe)

button to enter the filter cycle

programming mode. The LCD screen will display the following in the

upper right corner:

This means the system is ready to accept you changes to the start time

for cycle number one. Simultaneously, the large four-digit display in the

center of the screen displays the currently programmed start time for that

cycle. At this point, you have four options. You may:

1. Press

(UP)

or

(dOWN)

button to adjust the start time in

increments of 30 minutes.

2. Press

(CYCLe)

button to display and adjust each subsequent

cycles start time. With each press, the currently programmed status

will be shown in the large four digit display. To adjust any displayed

value, simply press the

(UP)

or (dOWN)

button.

3. Press

(SeLeCT)

button to move down the menu from Start

Time to Duration, with each press, the currently programmed

duration will be shown in the large four-digit display. Press

(UP)

or (dOWN)

button to adjust the duration in increments

of 15 minutes.

4. Press

(diSPLAY)

button to save changes and recall the main

water temperature display.

Note: If no button is pressed within 30 seconds, all changes are

recorded and the screen automatically returns to the standard water

temperature display.

*Note: Number will vary

according to which filter

cycle is being programmed.

1*