Sanyo PLC-XM100L User Manual
Page 28

PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications
28/28
7.8 Temp Read Command
Command “CR6” [CR]
Detail
Get the information of temperature inside a projector.
With several built-in temperature sensors, it can get all the temperatures at once.
Acceptable
“%1 _ %2 _ %3” [CR]
%1
%2
%3
%1 = Temp. of sensor 1
%2 = Temp. of sensor 2
%3 = Temp. of sensor 3
Temperature data basic format is “_00.0”. (“_” indicates a space)
When the temperature goes under 0, it starts with “-” instead of a
space like “-05.5” [CR].
When no temperature data returns due to hardware problems, it
starts with “E” like”E00.0” [CR].
With several built-in temperature sensors, the projector returns
the values in succession.
“_31.5_ _35.2_ 33.4 ” [CR]
The first sensor’s data is followed by one space and afterwards
the second sensor’s data.
Response
Unacceptable “?” [CR]
7.9 Lamp Mode Read Command
Command “CR7” [CR]
Detail
Get lamp mode.
In the projector with single lamp, get ON/OFF status of the lamp
Acceptable
“%1” [CR]
%1
“00” [CR] = Lamp is ON.
“01” [CR] = Lamp is OFF.
Response
Unacceptable “?” [CR]