PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications

12/28

6.5 POWER ON Command

Command “C00” [CR]

Detail

Power ON
When already Power is ON, no operation is started. When sending this
command during Countdown in process, Countdown is terminated.

Acceptable

[ACK] [CR]

Response

Unacceptable “?” [CR]

6.6 POWER OFF Command (Quick POWER OFF)

Command “C01” [CR]

Detail

Power OFF (Standby)
This command executes Quick Power OFF operation without displaying “Power
OFF?” message, which is displayed when Power is turned OFF with
ON/STAND-BY button of the projector or remote control.

Acceptable

[ACK] [CR]

Response

Unacceptable “?” [CR]

6.7 POWER OFF Command

Command “C02” [CR]

Detail

Power OFF (Standby)

This command works the same way as when Power is OFF with ON/STAND-BY
button of the projector and remote control.
(When the

command is sent once,

“Power OFF?” message is displayed. If this

command is sent again while “Power OFF?” message is displayed,

Power OFF

operation is executed.)

When sending this command during Countdown in process, Countdown is
terminated.

Acceptable

[ACK] [CR]

Response

Unacceptable “?” [CR]

6.8 INPUT 1 Command

Command “C05” [CR]

Detail

Select Input 1. This command works differently from the command by “Input 1”
key of the remote control. When Input 1 has been already selected, this
command does not execute the source switching; just for switching to Input 1.
Although projector returns “OK”, Input search is not executed with this command
while Input button is set to Mode2 or Mode3.

Acceptable

[ACK] [CR]

Response

Unacceptable “?” [CR]

6.9 INPUT 2 Command

Command “C06” [CR]

Detail

Select Input 2. This command works differently from the command by “Input 2”
key of the remote control. When Input 2 has been selected, this command does
not execute the source switching; just for switching to Input 2.
Although projector returns “OK”, Input search is not executed with this command
while Input button is set to Mode2 or Mode3.

Acceptable

[ACK] [CR]

Response

Unacceptable “?” [CR]