PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications

25/28

“10” [CR]

Status: Power Failure

When the power supply voltage inside the projector reaches abnormal status, the projector

is automatically turned off.

Abnormal power supply voltage includes;

-

Filter abnormal status

-

Shutter abnormal status

The projector returns “10” [CR], which indicates it enters Power OFF status due to Power

Failure.

In this case Fan also stops unlike Cooling Down status.

“28” [CR]

Status: Cooling Down in process due to Abnormal Temperature

When the inside temperature rises abnormally high, it automatically starts Cooling Down

operation. The projector returns “28” [CR].

Even if the temperature goes down during this process, the given Cooling Down process is

conducted.

“88” [CR]

Status: Standby after Cooling Down due to Abnormal Temperature

When the status becomes Standby after the temperature goes down by Cooling Down

operation invoked due to Abnormal Temperature, the projector returns “88” [CR]. This

indicates Abnormal Temperature caused turning to Standby status.

This status continues until the next operation is started; when Power On is executed, the

projector clears the information of Abnormal Temperature and normal operation starts.

“24” [CR]

Status: Power-Save Cooling Down in process

This indicates Power Management in the Setting menu is enabled and Power-Save

Cooling Down operation is in process.

During this time, any Functional Execution Command is invalid.

In this Power-Save Cooling Down function, the status moves to Power Save after the given

Cooling down operation.

Status: No signal Power-Save Cooling Down Power Save

Response: “00” “24” “04”

No signal status has passed for the time
set by power management timer

After about 90 sec.