7.5 Input Mode Read Command
Command “CR1” [CR]
Detail
Get currently selected Input No.
Acceptable
“%1” [CR]
%1
”1” = Input 1 is selected.
“2” = Input 2 is selected.
“3” = Input 3 is selected.
“4” = Input 4 is selected.(only for Networking-capable models)
Response
Unacceptable “?” [CR]
7.6 Lamp Time Read Command
Command “CR3” [CR]
Detail
Get total lamp running hours.
*return lamp operating time multiplied by the given coefficient (not actual used
time)
Acceptable
“%1” [CR]
%1
Display Lamp running hours with 5 digit numbers.
Example:
“00410” [CR] ---------- 410 hours
Response
Unacceptable “?” [CR]
7.7 Setting Read Command
Command “CR4” [CR]
Detail
Get screen setting status such as Ceiling/Rear.
Acceptable
“%1” [CR]
%1
“11” [CR] = Normal Screen Setting
“10” [CR] = Picture is top/bottom reversed. (Status: Rear & Ceiling
ON)
“01” [CR] = Picture is left/right reversed. (Status: Rear ON)
“00” [CR] = Picture is top/bottom and left/right reversed. (Status:
Ceiling ON
)
Response
Unacceptable
“?” [CR]