Sanyo PLC-XM100L User Manual
Page 11

PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications
11/28
6.4 Operation Requirements
6.4.1
In the following status of projector, Available Functional Execution Commands are limited.
Projector Status
Available Functional Execution Commands
Standby Mode
C00: POWER ON
Countdown in process
C00: POWER ON → Countdown is terminated
C01: POWER OFF
C02: POWER OFF → Countdown is terminated
C46: ZOOM -
C47: ZOOM +
C4A: FOCUS -
C4B: FOCUS +
C5D: LENS SHIFT UP
C5E: LENS SHIFT DOWN
C5F:LENS SHIFT LEFT
C60:LENS SHIFT RIGHT
When ZOOM+/-, FOCUS +/-, LENS SHIFTUP/
DOWN/LEFT/RIGHT are executed during Countdown
is in process, POINTER UP/DOWN(C3C/C3D)
become effective, and ZOOM/FOCUS/LENS SHIFT
become enable to control by POINTER UP/DOWN.
*Pointer Command(C3A/CA3B/C3C/C3D)
Cooling Down in process
NONE (No Execution)
Cooling Down due to Abnormal
Temperature
NONE (No Execution)
Abnormal Temperature Status
NONE (No Execution)
Abnormal Power Status
NONE (No Execution)
Abnormal Filter Status
NONE (No Execution)
Power-Save Cooling Down in process NONE (No Execution)
Power Save Status
C00: POWER ON
C01: POWER OFF
Cooling Down in process after OFF
operation due to Lamp Failure
NONE (No Execution)
Input button:Mode2 / Mode3 setting
Although transmit Input source commands, Input
search does not operate.
Note) in above status, the projector returns [ACK] [CR] even if it receives the other command.
6.4.2
Functional Execution Commands are invalid when projector is in standby and “Eco” mode
selected in Standby mode menu.