beautypg.com

Sanyo PLC-XM100L User Manual

Page 26

background image

PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications

26/28

“04” [CR]

Status: Power Save

This indicates it moves to Power-Save status by Power Management function as set in the

Setting menu.

“21” [CR]

Status: Cooling Down in process after OFF due to Lamp Failure

When the projector is turned off due to lamp failure, it automatically starts Cooling Down

operation. The projector returns “21” [CR]. “21” [CR] has been kept during Cooling Down

operation.

“81” [CR]

Status: Standby after Cooling Down due to Lamp Failure

The projector has recovered from Lamp Failure status. When the projector enters Standby

status after Cooling Down operation invoked due to lamp failure, it returns “81”. This indicates

the status turns to Standby due to lamp failure. This status continues until the next operation

is started; when Power On is executed, the projector clears the information of Lamp Failure

and normal operation starts.

“2C” [CR]

Status: Cooling Down in process due to Shutter management function

This indicates it has moved to Cooling down status according to the setting of Shutter

Management function in setting menu. During this time, Functional Execution Commands are not

accepted.

“8C” [CR]

Status: Standby after Cooling Down due to Shutter management function.

This value is returned when Cooling Down operation due to Shutter management has been

completed and the status has been moved to Standby. The status is kept until the next operation

starts. When projector is turned on again, it cancels the last status and starts normal operation.