beautypg.com

Power supply, Using a bp-l40/l40a/l60/l60a/l90/l90a battery pack – Sony 500WSPL User Manual

Page 46

background image

Chapter 2 Fitting and Connections

46

Chapter 2

Fitting and Connections

LOCK

Align these lines.

BP-L40/L40A/L60/L60A/L90/L90A

Power Supply

The following power supplies can be used with the
camcorder.
• BP-L40/L40A/L60/L60A/L90/L90A lithium-ion

battery pack

• NP-1B Ni-Cd Battery Pack (The DC-L1Battery

Adaptor is required.)

• BP-90A Ni-Cd Battery Pack (The DC-L90 Battery

Adaptor is required.)

• AC power (The AC-550/550CE, AC-DN1/DN2A or

CMA-8A/8ACE AC Adaptor is required.)

Alternatively, you can make combined use of internal
and external batteries, by mounting one of the above
batteries as an internal battery and connecting an
external battery that can be a BP-90A contained in a
DC-210 Battery Adaptor and connected to the DC IN
connector of the camcorder.

Using a BP-L40/L40A/L60/L60A/L90/L90A Battery Pack

With a battery pack, the camcorder will operate
continuously for the time shown below.
BP-L40/L40A: Approx. 70 minutes
BP-L60A: Approx. 140 minutes
BP-L90A: Approx. 230 minutes

Before use, charge the battery pack with a BC-L50/
L100/L100CE Battery Charger.

Notes on using the battery pack

• A warm battery pack may not be able to be fully

recharged.

• Even when fully charged, battery packs gradually

lose their charge naturally. Use the battery packs as
soon as possible after recharging.

• To prolong the life of battery packs, store them in a

cool place (about 20°C (68°F

)

), and charge in a place

with an ambient temperature between 10°C and 30°C
(50°F to 86°F).

• Before long-term storage, discharge the battery fully.

This extends the battery’s life.

• It is recommended that the BP-L40/L40A be used at

30 W or less. The specified capacity may not be
obtained if it is connected to the camcorder with
accessories which is operated at 30 W or higher,
especially when the ambient temperature is low.

• At low temperatures, the usable time of battery packs

decreases. When the ambient temperature is 0°C
(32°F), usable time decreases by about 10%.
(However, the usable time is affected by the power
consumption of the connected camcorder and the
usage status of the battery packs.) The usable time of
battery packs increases if they are warmed to the
room temperature (about 20°C (68°F)) before use at
low temperatures.

• If you use the BP-L40/L40A at temperatures of 0°C

(32°F) or below, when power consumption of the
camcorder and accessories is 40 W or higher (due to
using a video light, for example), power may break
after a short time (a few minutes). To increase the
usable time, store the BP-L40/L40A in a warm place
and power on the connected camcorder before the
BP-L40/L40A cools down.

• Compared to the BP-L40/L40A, the BP-L60/L60A/

L90/L90A offer better performance at low
temperatures. The BP-L60/L60A/L90/L90A are
recommended for use at low temperatures.

• Carrying a spare battery pack is recommended.

The BP-L40/L40A/L60/L60A/L90/L90A is free from
memory effect. There is no need to discharge it fully
before recharging.

Attaching the battery pack

1

Press the battery pack against
the rear of the camcorder,
aligning the side line of the
battery pack with the line on
the camcorder.