19

27-0027-0111

SCI P/N: 72A-196BAREM Series

72A-190BQREM Series

Networking Functions

@BULC B,?

Read High Threshold Current Bank B

#BULC 22.5

@BULC C,?

Read High Threshold Current Bank C

#BULC 22.5

@BULC T,?

Read High Threshold Current Bank T

#BULC 77.5

@BLLV A,?

Read Low Threshold Voltage Bank A

#BLLV 135.3

@BLLV B,?

Read Low Threshold Voltage Bank B

#BLLV 135.3

@BLLV C,?

Read Low Threshold Voltage Bank C

#BLLV 135.3

@BLLC A,?

Read Low Threshold Current Bank A

#BLLC 10.0

@BLLC B,?

Read Low Threshold Current Bank B

#BLLC 10.0

@BLLC C,?

Read Low Threshold Current Bank C

#BLLC 10.0

@BLLC T,?

Read Low Threshold Current Bank T

#BLLC 22.0

@MAXC A,?

Read Maximum Current Bank A

#MAXC 22.5

@MAXC B,?

Read Maximum Current Bank B

#MAXC 22.5

@MAXC C,?

Read Maximum Current Bank C

#MAXC 22.5

@MAXC T,?

Read Maximum Current Bank T

#MAXC 90.0

@MINC A,?,

Read Minimum Current Bank A

#MINC 15.0

@MINC B,?

Read Minimum Current Bank B

#MINC 15.0

@MINC C,?

Read Minimum Current Bank C

#MINC 15.0

@MINC T,?

Read Minimum Current Bank T

#MINC 45.0

@MAXC A,0

Reset Maximum Current Bank A

#MAXC OK

@MAXC B,0

Reset Maximum Current Bank B

#MAXC OK

@MAXC C,0

Reset Maximum Current Bank C

#MAXC OK

@MAXC T,0

Reset Maximum Current Bank T

#MAXC OK

@MINC A,999.9

Reset Minimum Current Bank A

#MINC OK

@MINC B,999.9

Reset Minimum Current Bank B

#MINC OK

@MINC C,999.9

Reset Minimum Current Bank C

#MINC OK

@MINC T,999.9

Reset Minimum Current Bank T

#MINC OK