Telnet Configuration

Password

Setting the Telnet configuration password prevents unauthorized access

of the setup menu via a Telnet connection to port 9999. The password

is limited to 32 characters. Option 7 allows the user to change the telnet

configuration password.

Testing the IP

Address

Configuration

Once the IP address is assigned, you should test the IP address

configuration to be sure it works as configured.

Prerequisite

This procedure assumes that you have configured the device server with

an IP address.

Procedure

1.

Access the command line of a PC or other networked device.

2.

Issue the following command: ping ip-address (where ip-address

is the address you assigned to the device server).

Example:

ping 192.168.1.110

A reply should be returned.

LAN Module

Configuration Using

a Telnet Connection

To configure the LAN Module over the network, establish a Telnet

connection to port 9999. From the Windows Start menu, click Run and

type the following command, where x.x.x.x is the IP address and 9999 is

the LAN Module’s fixed network configuration port number.

telnet x.x.x.x 9999

Note: Be sure to include a space between the IP address and 9999.

The default IP Address is 192.168.1.110, so the command should look

like “telnet 192.168.1.110 9999”. At login, type “root” for the username

and “1234” for the password. This command will launch the configuration

menu. After the first sentence appears, press [Enter] to go into the setup

mode.