Applicable Models

PFV-SP3100 Signal Processing Unit
PFV-SP3300 Signal Processing Unit

Supplied Accessories

Installation guide (1)
Installation manual (1)
3.5 inches floppy disk (1)

Specifications

- Inputs/outputs -

Reference inputs :

Supplied through the REF IN
connectors on the PFV-SP Series signal
processing units
REF IN connectors (BNC type) (2)
Black Burst or Tri-level sync signal

Remote

CONTROL LAN:

RJ-45 (1), Ethernet 100Base-TX

DATA LAN:

RJ-45 (1), Ethernet
100Base-TX/10Base-T

RS-422:

D-sub 9-pin (1)

GPI:

Mini D-sub 15-pin (1)

- General -

Power requirements:

+12 V DC: 0.8 A

Operating temperature:

5 to 40 °C (41 to 104 °F)

Storage temperature:

-20 to 60 °C (-4 to 104 °C)

Operating humidity:

10 to 90% (no condensation)

Dimensions

Board (H x W):

112.2 x 388.3 mm
( 4 1/2 x 15 3/8 inches)

Connector panel (W x H x D):

130 x 152.5 x 19 mm
(5 1/8 x 6 1/8 x 25/32 inches)

Mass

Board:

Approx. 350 g (12 oz)

Connector panel:

Approx. 130 g (5 oz)

With an HKSP-300 processing module controller installed,
the function boards accommodated within the same
PFV-SP Series processing units can be controlled from a
UCP-8060 universal control panel over an Ethernet-based
network. A redundant CPU is available by installing two
HKSP-300 boards. The newly developed set-up data
backup function retains the settings of the function boards
when they have been exchanged. Set-up for networking
can be carried out through a connected PC.

Features

*Networking applications; Enables the setting, control, and
up/downloading of the set-up data of other HKSP function
boards in a PFV-SP Series signal processing unit when
used in combination with a UCP-8060 universal control
panel connected via a Ethernet 100BASE-TX based
network, Interactively up/downloads set-up data via a
Sony System Manager, Multiple control panels can
operate with multiple processors *Redundant CPU
available by installing two HKSP-300 boards *Auto
backup function for set-up data; Periodically backs up the
set-up data of function boards and restores to any
exchanged boards *Eight inputs and four outputs of GPI
interface

The HKPF-SP/HKSP function boards install in PFV-SP Series Signal
Processing Units in any combination with other HKPF-SP/HKSP function
boards.

54

Inter

face Pr

ocessor SP Series

Interface Processor SP Series

HKSP-300

Processing Module Controller

Front Panel

Rear Panel

RS-422

GPI

DATA LAN

CONTROL LAN

Control Panel

UCP-8060

REF A

REF B

INT BUS

CPU

HKSP/HKPF-SP Series

Option Boards

*SGC_0043-0068 02.3.16 5:02 PM Page 54