Technical References
Phantom function (salvo function)
This function allows the switching of multiple crosspoints at the same time with a single button
operation. The following two types of settings can be made:
(1) “Local phantom”: Registers up to 64 crosspoints for each remote control panel.
(2) “Global phantom”: Registers up to 2,800 crosspoints for the routing switchers set by the
primary stations.
Names can be set for phantoms (groups of crosspoints switched simultaneously). Since
local phantoms are registered for each remote control panel, the same name can be used
for a different group of crosspoints on each remote control panel.
On the other hand, global phantoms are useful when there are many crosspoints to switch
simultaneously, or when sharing the same phantom across multiple remote control panels.
Also, the number of phantoms set for each unit can be increased by combining global
phantoms and local phantoms.
SET INHIBIT TABLE
DEST.
SOURCE
001
01--08
09--16
17--24
25--32
33--40
41--48
49--56
57--64
OUT001
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
--------
--------
--------
--------
OUT002
--------
--------
--------
--------
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT003
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT004
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT005
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT006
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT007
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT008
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
DEST.
SOURCE
009
01--08
09--16
17--24
25--32
33--40
41--48
49--56
57--64
OUT009
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT010
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT011
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT012
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT013
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT014
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT015
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT016
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
HDS-X5800 V1.00
F1: SEARCH
F2: JUMP
F3: LEFT
F4: RIGHT
STATION NUMBER 1
Ctrl-E: RETURN TO MENU
“-” mark is an inhibited crosspoint.
Figure-2
Crosspoint disabling function
Input/output system protection functions
(protect and secret functions)
There are two protection functions:
“Protect” function prevents the output destination from being re-assigned from another remote
control panel.
“Secret” function ‘hides’ the input sources that cannot be selected to any destination from any
remote control panel.
Crosspoint disabling function
This function inhibits individual crosspoints to limit the availability of each source to individual
destinations.