beautypg.com

3 regulation for natural gas, 4 regulation for town gas, Instructions for the installer – Smeg SDR575XG5 User Manual

Page 11

background image

Instructions for the installer

31

5.3

Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of

20 mbar. To allow the unit to work with this type of gas, perform the
same operations described in paragraph “5.2

Regulation for LPG”, but

choose the nozzles and regulate the primary air for natural gas, as
shown in the following table and in paragraph “5.5

Regulation of

primary air”. After the regulations have been carried out, restore the
seals with sealing wax or equivalent material.

Burner

Rated heating

capacity

Natural gas – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Auxiliary (1)

1.05

73

380

Semirapid (2)

1.65

92

380

Rapid (3)

2.55

115

650

Rapid large (4)

3.1

126

750

Fish pan (7)

2.0

100

750

Ultra rapid (5)

3.3

130

1200

Internal

1.05

73

380

Double
crown
(6)

External

3.9

140

1200

5.4

Regulation for town gas

To allow the unit to work with this type of gas, perform the same

operations described in paragraph “5.2

Regulation for LPG”, but

choose the nozzles and regulate the primary air for town gas, as shown
in the following table and in paragraph “5.5

Regulation of primary air”.

Attention! Only units with safety valves can be used with town gas
G110.

Burner

Rated heating

capacity

Town Gas 110 - 8 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Auxiliary (1)

1.05

132

380

Semirapid (2)

1.65

165

380

Rapid (3)

2.55

210

650

Rapid large (4)

3.1

240

750

Fish pan (7)

2

190

750

Ultra rapid (5)

3.3

250

1200

Internal

1.05

132

380

Double crown
(6)

External

3.9

290

1200