Regulation for LPG

Loosen screw A and push support B all the way. Use a double head

wrench to remove nozzle C and assemble the suitable one, following
the instructions indicated in the reference charts, with respect to the
type of gas to use. The screwing torque of the nozzle should never
exceed 3 Nm. Reposition support B so that nozzle C is covered
perfectly.
Move the Venturi tube D to regulate the air flow until distance “X” is
reached indicated in the chart in paragraph “5.4 Regulation of primary
air” and then secure the tube by means of screw A. After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.

Rated

LPG – G30/G31 28/37 mbar

Burner

heating

capacity

Nozzle

Reduced

diameter

By-pass

Flowrate

Flowrate

flowrate

1/100

1/100 mm

g/h G30

g/h G31

(W)

mm

Auxiliary (1)

1.05

48

30 (1)

380

76

75

Semirapid (2)

1.65

62

30 (1)

380

120

118

Rapid (3)

2.55

76

37 (2)

650

185

182

Rapid large (4)

3.1

85

43

750

225

222

Fish pan (7)

2

67

43 (3)

750

145

143

Ultra rapid (5)

3.3

87

55 (4)

1200

240

236

Double Internal

1.15

48

30 (1)

380

84

82

crown

External

3.8

92

55 (4)

1200

276

271

(6)

(1)= 33 for valveless appliances.
(2)= 40 for valveless appliances.
(3)= 45 for valveless appliances.
(4)= 65 for valveless appliances.