Contract or, Trouble shooting – Skuttle Indoor Air Quality Products 60-2 User Manual
Page 27

P
ROBLEM
E
VIDENCE
S
OLUTIONS
(
S
)
Low Humidity
Low water level (less than
• See Plumbing and Setting Water
2-3/8" deep)
Level, steps 4 & 5
No water in reservoir
• Turn water on at saddle valve
• Turn off water main and check
for possible obstruction in saddle
valve or float valve
Humidifier heater is not
• Make sure the humidifier is
operating
plugged in
• Set the humidistat higher
• Check for blown circuit breaker
• Check all external wiring connec-
tions
• Check for low water level
• Check the humidistat switch for
continuity
• Call a professional HVAC con-
tractor
Rapid air changes (drafts)
• Keep doors and windows closed
(cold, dry air is an added load
on the humidifier)
• Close fireplace damper when
not in use
• Keep exhaust fan running time
to a minimum
• Seal around doors and windows
High Humidity
Condensation on walls
• Turn humidistat off
• Turn water to humidifier off
until condensation is evaporated
Heavy condensation on
• Turn humidistat down enough
windows
to eliminate condensation (this
may be a temporary condition
caused by moisture from bathing,
mopping, cooking, etc.)
Humidifier Overflows
High water level
• Inspect valve seat for defects
• Inspect valve nozzle for cracks
or erosion
• Readjust water level (see
Plumbing and Setting Water
Level
• Make sure humidifier is level
27
CONTRACT
OR
Trouble Shooting
Table 1