P

ROBLEM

E

VIDENCE

S

OLUTIONS

(

S

)

Low Humidity

Low water level (less than

• See Plumbing and Setting Water

2-3/8" deep)

Level, steps 4 & 5

No water in reservoir

• Turn water on at saddle valve
• Turn off water main and check

for possible obstruction in saddle
valve or float valve

Humidifier heater is not

• Make sure the humidifier is

operating

plugged in

• Set the humidistat higher
• Check for blown circuit breaker
• Check all external wiring connec-

tions

• Check for low water level
• Check the humidistat switch for

continuity

• Call a professional HVAC con-

tractor

Rapid air changes (drafts)

• Keep doors and windows closed

(cold, dry air is an added load
on the humidifier)

• Close fireplace damper when

not in use

• Keep exhaust fan running time

to a minimum

• Seal around doors and windows

High Humidity

Condensation on walls

• Turn humidistat off
• Turn water to humidifier off

until condensation is evaporated

Heavy condensation on

• Turn humidistat down enough

windows

to eliminate condensation (this
may be a temporary condition
caused by moisture from bathing,
mopping, cooking, etc.)

Humidifier Overflows

High water level

• Inspect valve seat for defects
• Inspect valve nozzle for cracks

or erosion

• Readjust water level (see

Plumbing and Setting Water
Level

• Make sure humidifier is level

27