background image

14

Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006

4. Connect Ethernet cables to the “NET” connectors as required for your Gigabit

Ethernet or a management network.

The connectors labeled “NET 0” through “NET 3” are Gigabit Ethernet ports.

The port labeled “NET MGT” is a 10/100 Ethernet port that can connect your
system to a management network.

5. If desired, connect an RJ-45 serial port cable to the “SERIAL MGT” connector.

Note the following considerations for the serial port and serial port cabling:

The default serial port speed is 9600 baud with no flow control.

These servers use the same pinout as the RJ45 port on the RSC/ALOM/ALOM
Plus cards on Sun Netra™ and other Sun Fire systems.

There is a compatible Sun RJ45-to-DB9 Adapter shipped with the server, part
number 530-3100.

An alternative, compatible cable is the CISCO 72-3383-01 console cable.

6. Continue with

“Powering On and Powering Off the Server” on page 15

.