background image

-23-

Model W1815 (Mfg. Since 10/10)

SE

RV

IC

E

Miter Gauge Calibration

At 90˚ the miter gauge should be perpendicular to the

face of the wheel when it is mounted in the table slot. If

it is not, follow this procedure to recalibrate it.

Tools Needed:

Machinist's Square ..............................................1

Phillips Head Screwdriver .....................................1

To calibrate the miter gauge, do these steps:

1. DISCONNECT MACHINE FROM POWER!

2. Use a try square or machinist’s square with one edge

against the face of the miter gauge and the other

against the disc face, as shown in

Figure 18.

3. Loosen the lock knob on the miter gauge and adjust

the face of the miter gauge so it is flush with the

edge of the square, tighten the gauge lock knob, and

verify the setting.

4. Loosen the degree scale pointer, position the pointer

on 90˚, and retighten the screw.

5. Recheck the miter scale accuracy with the square.

Figure 18. Squaring miter gauge to disc.