beautypg.com

Rs-232c commands, Rs-232c interface – JVC BR-DV6000 User Manual

Page 86

background image

86

Blank “Table” boxes below denote that these com-
mands exist for both command tables.

B : BASIC TABLE,
J1 : JVC TABLE-1

RS-232C INTERFACE

– RS-232C commands –

An optional RS-232C interface board SA-K46U can be installed to BR-DV6000 and connected to a
personal computer. Data transmitted and received via the RS-232C interface enables the PC to
control the VCR and gather status and operating information.

Preparation

To control the VCR by the RS-232C interface, the following settings are required.

• Set REMOTE SEL 232 in the REMOTE (1/2) Menu screen to ON.
• Set the REMOTE/LOCAL switch on the front panel to REMOTE.

Command tables

BR-DV6000 is controlled according to the following two command tables (BASIC, JVC-1).

Command

Description

F6

JVC-1 TABLE ON : Hereafter, JVC TABLE-1 is followed.

F7

BASIC TABLE ON : Hereafter, BASIC TABLE is followed. JVC TABLE-1 is turned OFF.

VCR operation commands

These commands are used to operate the VCR. When a

command is received correctly, the VCR returns ACK (0Ah)
and enters the mode corresponding to the command.
(Example) Playback

R

X

D

3A

0A

T

X

D

B
B
B
B

B
B
B
B
B

3A
3B
3C
3D
3E
3F

46

47

48

49

4A
4B
4C
4D
4E
4F

50

51

52

53

54

55

58

PLAY

: Play

FWD x 2

: 2x play

FWD x 0.2

: 0.2x play

F-STILL

: Pause

FWD x 9/10

: 9(10) x play (PAL)

STOP

: Stop

IN SHIFT +

: Shifts the IN point to the

+ direction.

IN SHIFT –

: Shifts the IN point to the

– direction.

OUT SHIFT +

: Shifts the OUT point to

the + direction.

OUT SHIFT –

: Shifts the OUT point to

the – direction.

REV x 1

: Reverse play

REV x 2

: 2x reverse play

REV x 0.2

: 0.2x reverse play

R-STILL

: Pause

REV x 9/10

: 9(10) x reverse play

STILL

: Pause

IN ENTRY

:

Registers the current time as the IN point.
OUT ENTRY

:

Registers the current time as the OUT point.
IN FLAG RESET

:

Cancels the registered IN point.
OUT FLAG RESET :
Cancels the registered OUT point.
IN FLAG RECALL :
Validates the cancelled IN point.
OUT FLAG RECALL:
Validates the cancelled OUT point.
GO TO IN

:

Cues up the point specified with IN ENTRY
(50) and IN DATA PRESET (E3). When the
tape is cued, COMPLETE (01) is returned.
When the specified point cannot be found,
NOT TARGET (05) is returned.

J1
J1

59

5A

5B

7B
7C
A0
A1
A2
A3

AB

AC

AD

AE

GO TO OUT :
Cues up the point specified with OUT ENTRY
(51) and OUT DATA PRESET (E4).When the
tape is cued, COMPLETE (01) is returned.
When the specified point cannot be found,
NOT TARGET (05) is returned.
MEMORY

:

Registers the current counter value as
the cue-up point of MEMORY
SEARCH (5B).
MEMORY SEARCH :
Cues up the point specified with MEMORY
(5A). When the tape is cued, COMPLETE
(01) is returned. When the specified point
cannot be found, NOT TARGET (05) is re-
turned.
OPERATE ON

: Operating mode ON

OPERATE OFF

: Operating mode OFF

STANDBY ON

: Standby ON

STANDBY OFF

: Standby OFF

PREROLL

: Preroll

EJECT

:

Ejects the cassette tape. When the tape has
been ejected, CASSETTE OUT (03H) is
returned.
FF

:

Fast-forwards the tape.
REW

:

Rewinds the tape.
F-FIELD STEP

:

Advances one frame. This command should
be transmitted in the Play-Pause mode.
Field-advances when STL/F.ADV MODE is
set to FIELD. Otherwise, this command
frame-advances.
R-FIELD STEP

:

Reverses one frame. This command should
be transmitted in the Play-Pause mode.
Field-advances when STL/F.ADV MODE is
set to FIELD. Otherwise, frame-advances.

Table

Command

Description

Table

Command

Description

DV6000U_72-104_Eng.p65e

06/03/03, 11:42 PM

86