beautypg.com

Idp sensor leds, System status leds, Management and high availability port leds – Juniper Networks IDP 800 User Manual

Page 28: Table 6, Idp sensor power supplies, Table 7, Front panel system status leds

background image

IDP 75, 250, 800, and 8200 Installation Guide

14

„

IDP Sensor LEDs

IDP Sensor LEDs

This section describes the LEDs for the following IDP sensor components:

„

System status

„

Management and high availability ports

„

Traffic ports

„

Hard drives

„

Power supply (back panel)

System Status LEDs

The IDP 75, 250, 800, and 8200 sensors each have three system status lights on
the front panel to indicate power, hard drive activity, and overheating. See Table 7.

Management and High Availability Port LEDs

Management and high availability (HA) ports each have two LEDs—LINK and
TX/RX (Figure 8). Management ports are on all sensors. HA ports are available on
the IDP 250, 800, and 8200 sensors only. Table 8 describes the LEDs for
management and HA ports

Table 6: IDP Sensor Power Supplies

IDP Sensor

Power Supplies

75

One fixed power supply.

250

One removable power supply.

800, 8200

Two removable hot-swappable power supplies.

Both sensors are shipped with the AC power supply.

The DC power supplies are optional as FRUs.

Table 7: Front Panel System Status LEDs

Color

Function

LED Action Status Description

Green

Power

„

Stays on when powered on.

„

Stays off when powered off.

Yellow

Hard drive activity

Flickers with activity.

Red

Fault

„

Blinks slowly when a fan fails.

„

Blinks quickly when system is overheated.

„

Stays on when the power supply fails.

„

Stays off when the system is functioning at a normal
temperature.