Cleaning and replacing the filter – JVC DLA-M5000LU User Manual
Page 58
58
DLA-M5000CLU (Re)/ LCT0978-001B / ENGLISH
Filter Maintenance and Light-Source Lamp
Replacement
Cleaning and Replacing the Filter
The filters should be cleaned periodically. If they are heavily stained, do not become clean if cleaned, or are damaged,
replace them with new filters (Parts number: LC30505); otherwise, dirt and dust may get inside, possibly causing an adverse
effect on the screen and preventing you from enjoying clear pictures.
■ The projector has two filters installed, one on the right side and the other on the back.
1
Bring the projector into stand-by state, and turn off the MAIN POWER switch.
Put the projector into stand-by, and make sure the STAND BY indicator is lit, then tun off the MAIN POWER switch. After
that, disconnect the power cord from the wall outlet and the projector. For detailed procedures, refer to “Turning off the
power” (page 24).
2
Remove the filter cover screws.
Using a Phillips screwdriver, remove the six screws fixing each filter.
Two filters are used, one on the right side and the other on the back of the projector.
3
Remove the filters.
To remove the filter, pinch the center portion of the filter with your fingers and pull it toward you.
(The filter is held by four tabs.)
There are two filters used.
Note
• If the filter is clogged with dirt, etc., the projector
goes into an emergency mode (the EMERGENCY
indicator blinks).
• So, clean the filter periodically. For the emergency
mode, refer to pages 7 and 23.
(To be continued on the next page)
DLA-M5000LU&SCU Eng Re.book Page 58 Tuesday, March 12, 2002 3:56 PM