4 definition of terms, Definition of terms, Terms and descriptions – Intel 5400 Series User Manual

Page 10: Table 1-1. reference documents (sheet 2 of 2), Table 1-2. terms and descriptions (sheet 1 of 2)

background image

Introduction

10

Quad-Core Intel® Xeon® Processor 5400 Series TMDG

Note:

Contact your Intel field sales representative for the latest revision and order number of this document.

1.4

Definition of Terms

Clovertown_Harpertown_Wolfdale-DP Processor Enabled Components

CEK Thermal Models (in Flotherm* and Icepak*)

Available electronically

Clovertown_Harpertown_Wolfdale-DP Processor Package Thermal

Models (in Flotherm and Icepak)

Available electronically

RS - Wolfdale Processor Family BIOS Writers Guide (BWG)

See Note following table.

Thin Electronics Bay Specification (A Server System Infrastructure (SSI)

Specification for Rack Optimized Servers

www.ssiforum.com

Table 1-1.

Reference Documents (Sheet 2 of 2)

Document

Comment

Table 1-2.

Terms and Descriptions (Sheet 1 of 2)

Term

Description

Bypass

Bypass is the area between a passive heatsink and any object that can act to form a

duct. For this example, it can be expressed as a dimension away from the outside

dimension of the fins to the nearest surface.

DTS

Digital Thermal Sensor replaces the Tdiode in previous products and

uses the same

sensor as the PROCHOT# sensor to indicate the on-die temperature. The temperature

value represents the number of degrees below the TCC activation temperature.

MSR

The processor provides a variety of model specific registers that are used to control and

report on processor performance. Virtually all MSRs handle system related functions and

are not accessible to an application program.

FMB

Flexible Motherboard Guideline: an estimate of the maximum value of a processor

specification over certain time periods. System designers should meet the FMB values to

ensure their systems are compatible with future processor releases.

FSC

Fan Speed Control

IHS

Integrated Heat Spreader: a component of the processor package used to enhance the

thermal performance of the package. Component thermal solutions interface with the

processor at the IHS surface.

LGA771 Socket

The Quad-Core Intel® Xeon® Processor 5400 Series interfaces to the baseboard

through this surface mount, 771 Land socket. See the LGA771 Socket Mechanical

Design Guide for details regarding this socket.

P

MAX

The maximum power dissipated by a semiconductor component.

PECI

A proprietary one-wire bus interface that provides a communication channel between

Intel processor and chipset components to external thermal monitoring devices, for use

in fan speed control. PECI communicates readings from the processors Digital Thermal

Sensor. PECI replaces the thermal diode available in previous processors.

Ψ

CA

Case-to-ambient thermal characterization parameter (psi). A measure of thermal

solution performance using total package power. Defined as (T

CASE

– T

LA

) / Total

Package Power. Heat source should always be specified for Ψ measurements.

Ψ

CS

Case-to-sink thermal characterization parameter. A measure of thermal interface

material performance using total package power. Defined as (T

CASE

– T

S

) / Total

Package Power.

Ψ

SA

Sink-to-ambient thermal characterization parameter. A measure of heatsink thermal

performance using total package power. Defined as (T

S

– T

LA

) / Total Package Power.

T

CASE

The case temperature of the processor, measured at the geometric center of the topside

of the IHS.

T

CASE

_

MAX

The maximum case temperature as specified in a component specification.

TCC

Thermal Control Circuit: Thermal monitor uses the TCC to reduce the die temperature

by using clock modulation and/or operating frequency and input voltage adjustment

when the die temperature is very near its operating limits.