Receive adjustment, 4 receive adjustment – Icom IC-F5061 User Manual
Page 19
6 - 6
6-4 RECEIVE ADJUSTMENT
Select an adjustment item using [
↑] / [↓] keys, then set to the specifi ed value using [←] / [→] keys on the connected PC’s keyboard.
ADJUSTMENT
ADJUSTMENT CONDITION
UNIT
LOCATION
VALUE
RECEIVE
SENSITIVITY
[BPF (T1) C]
[BPF (T2) C]
NOTE:
“RECEIVE SENSITIVITY” must be adjusted before “S-METER.” Otherwise, “S-METER” will not be
adjusted properly.
1
• Channel
: CH 3
• Connect the SSG to the antenna connec-
tor and set as;
Frequency
: 136.000 MHz
Level
: +20 dBµ
†
(–87 dBm)
Modulation
: 1 kHz
Deviation
: ±3.5 kHz
• Receiving
SP jack Connect the SINAD meter
with an 4
Ω load to the SP
jack.
Minimum distortion
level
CONVENIENT:
The “RECEIVE SENSITIVITY” can be adjusted automatically.
1: Put the cursor on “[BPF C ALL]” and push [ENTER] key.
2: The connected PC tunes BPF’s to peak levels automaticaly.
S-METER
(S3 level)
[RSSI]
1
• Channel
: CH 3
• Connect the SSG to the antenna connec-
tor and set as;
Frequency
: 136.000 MHz
Level
: +23 dBµ
†
(–84 dBm)
Modulation
: 1 kHz
Deviation
:
±3.5 kHz
• Receiving
Push the [ENTER] key on the connected PC’s keyboard to set
“S3” level.
(S1 level)
2
• Set the SSG as;
Level
: –7 dBµ
†
(–114 dBm)
• Receiving
Push the [ENTER] key again to set “S1” level.
SQUELCH
[SQL]
1 • Channel
: CH 3
• Close the squelch by adjusting the value of
[SQL] item on the CS-F5060 ADJ’s screen.
• Connect the SSG to the antenna connec-
tor and set as;
Frequency
: 136.000 MHz
Level
: –14 dBµ
†
(–121 dBm)
Modulation
: 1 kHz
Deviation
:
±3.5 kHz
• Receiving
External
speaker
Connect an 4
Ω speaker to
the SP jack.
Close the squelch by
increase the value of
[SQL].
Set the [SQL] to the
value that the audio
signals just appear.
†;
The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.