6 - 4

6-2 FREQUENCY ADJUSTMENT

Select an adjustment item using [

↑] / [↓] keys, then set to the specifi ed value using [←] / [→] keys on the connected PC’s keyboard.

ADJUSTMENT

ADJUSTMENT CONDITION

UNIT

OPERATION

VALUE

PLL LOCK
VOLTAGE
(adjustment)
[RX LVA1]

1

Set the preset value of [LV (RX1)], [LV (RX2)] and [LV (TX)] to “204 [4.00V]” on the adjustment software.

2

• Channel
• Receiving

: CH 1

PC

screen

Click [Reload (F5)] button, then
check the “LVIN” item on the
CS-F5060 ADJ’s screen as below.

4.00 V

[RX LVA2]

3

• Channel
• Receiving

: CH 2

[TX LVA]

4

• Channel
• Transmitting

: CH 2

CONVENIENT:

The “PLL LOCK VOLTAGE” can be adjusted automatically.

1: Set the Lock voltage preset ([LV RX1], [LV RX2], [LV TX]) to “204 (4.00 V).”
2: Put the cursor on [RX LVA1], [RX LVA2] and [TX LVA], then push the [ENTER] key on the connected PC’s keyboard.

PLL LOCK
VOLTAGE
(verify)

1 • Channel

• Receiving

: CH 3

PC

screen

Click [Reload (F5)] button, then
check the “LVIN” item on the
CS-F5060 ADJ’s screen.

0.8–1.6 V

(Verify)

2 • Channel

• Receiving

: CH 4

3 • Channel

• Transmitting

: CH 3

REFERENCE
FREQUENCY
[REF]

1 • Channel

: CH 2

Top

panel

Loosely couple a frequency
counter to the antenna connector.

174.000000 MHz

• Connect an RF power meter to the

antenna connector.

• Transmitting

NOTE: The above screen is an example only.

Each item’s voltage will

appear when pushing [Update] button.

PLL LOCK VOLTAGE
will be appeared here

This manual is related to the following products: