beautypg.com

Manitowoc Ice S User Manual

Page 47

background image

Section 4

Maintenance

Part Number 000000966

4-5

Step 10 Mix a solution of sanitizer and warm water.

Step 11 Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a cloth or sponge
to liberally apply the solution to all surfaces of the
removed parts or soak the removed parts in the
sanitizer/water solution. Do not rinse parts after
sanitizing.

Step 12 Use 1/2 of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and bin
(or dispenser). Use a cloth or sponge to liberally apply
the solution. When sanitizing, pay particular attention to
the following areas:

Side walls

Base (area above water trough)

Evaporator plastic parts - including top, bottom and
sides

Bin or dispenser

Do not rinse the sanitized areas.

Step 13 Replace all removed components.

Step 14 Reapply power to the ice machine and place
the toggle switch in the CLEAN position.

Step 15 Wait about two minutes or until water starts to
flow over the evaporator. Add the proper amount of
Manitowoc Ice Machine Sanitizer to the water trough by
pouring between the water curtain and evaporator.

Step 16 The ice machine will stop after the sanitize
cycle (approximately 30 minutes). Place the toggle
switch in the OFF position and disconnect power to the
ice machine.

Step 17 Repeat step 6.

Step 18 Mix a solution of sanitizer and warm water.

Step 19 Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a cloth or sponge
to liberally apply the solution to all surfaces of the
removed parts or soak the removed parts in the
sanitizer/water solution. Do not rinse parts after
sanitizing.

Step 20 Use 1/2 of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and bin
(or dispenser). Use a cloth or sponge to liberally apply
the solution. When sanitizing, pay particular attention to
the following areas:

Side walls

Base (area above water trough)

Evaporator plastic parts - including top, bottom and
sides

Bin or dispenser

Do not rinse the sanitized areas.

Step 21 Install the removed parts, restore power and
place the toggle switch in the ICE position.

Solution Type

Water

Mixed With

Sanitizer

6 gal. (23 l)

4 oz (120 ml) sanitizer

Model

Amount of Sanitizer

S300/S320/S420

3 ounces (90 ml)

S450/S500/S600/S850/

S1000/S1200

3 ounces (90 ml)

S1400/S1600/S1800

6 ounces (180 ml)

!

Warning

Disconnect the electric power to the ice machine at
the electric service switch box..

Solution Type

Water

Mixed With

Sanitizer

6 gal. (23 l)

4 oz (120 ml) sanitizer