Warning, Disassembly procedures – Maytag MAH9700AW* User Manual
Page 36
36
16025909 Rev. 0
©2005 Maytag Services
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
Disassembly Procedures
WARNING
!
Outer Tub and Spinner Removal
1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Remove Console.
4. Remove Front Panel.
5. Remove Back Cover.
6. Remove Pump Hose.
7. Remove the Drain Hose
8. Remove the two 13mm bolts securing the Rear Struts
to the base.
9. Rotate the struts up against the bottom of the tub to
ease removal of the tub assembly.
NOTE: The rear struts can be identified by the green
sleeve.
10. Remove two each side 13mm bolts securing Counter
Weights.
NOTE: Torque bolts to 11-22 ft lbs. during installtion.
11. Remove wire harness connectors for the heater,
Themistor and ground.
12. Remove two 13mm bolts securing the Front Struts to
base and rotate up against the bottom of the tub.
13. Insert a board or boards across the bottom of the
washer frame to use as a support when removing the
tub assembly.
1x12 - 32” long