Primary current protection
Secondary current protection
High-pressure protection
Defrosting in cooling
3 times
Lighting
Discharge temperature
protection
•
Check refrigerant circuit and refrigerant amount.
•
Refer to 10-6.
G
"Check of LEV".
•
Refer to 10-6.
B
"Check of outdoor thermistors".
4 times
Lighting
Low discharge
temperature protection
•
Refer to 10-6.
G
"Check of LEV".
•
Check refrigerant circuit and refrigerant amount.
5 times
Lighting
Cooling high-pressure
protection
This symptom does not mean any abnormality of the
product, but check the following points.
•
Check if indoor filters are clogged.
•
Check if refrigerant is short.
•
Check if indoor/outdoor unit air circulation is short cycled.
-
-
These symptoms do not mean any abnormality of the
product, but check the following points.
•
Check if indoor filters are clogged.
•
Check if refrigerant is short.
•
Check if indoor/outdoor unit air circulation is short cycled.
Twice
Lighting
Once
Lighting
When the discharge temperature exceeds 100
:
during operation.
When the frequency of the compressor is kept 80Hz or more and
the discharge temperature is kept under 39
:
for more than 20
minutes.
When the outdoor heat exchanger temperature exceeds 58
:
during operation.
9 times
Lighting
Inverter check mode
Lighting
Lighting
Normal
When the unit is operated with emergency operation switch.
-
When the input current exceeds 15A.
When the current of the compressor exceeds 15A.
When the indoor gas pipe temperature exceeds 45
:
during heating.
When the indoor gas pipe temperature falls 3
:
or below during cooling.
LED1(Red) LED2(Yellow)
Abnormal point / Condition
Correspondence
Indication
Condition
Outdoor unit
operates.
Outdoor unit
operates
No. Symptom
20
21
22
23
24
25
26