11-time flash

• Check the connecting
wire between outdoor
electronic control
P.C. board and power
board.

• Replace the power
board.

• Check the connecting
wire among electronic
control P.C. board,
noise filter P.C. board
and power board.

• Replace the power
board.

When the communication between
boards protection stop is
continuously performed twice.

Communication error occurs
between the electronic control P.C.
board and power board for more
than 10 seconds.

Current sensor protection stop is
continuously performed twice.

When a short or open circuit is
detected in the current sensor
during compressor operating.

The protection stop of the zero
cross detecting circuit is
continuously performed 10 times.

When zero cross signal cannot be
detected while the compressor is
operating.

When a failure is detected in the
operation of the converter during
operation.

When the bus-bar voltage exceeds
400V or falls to 200V or below
during compressor operating.

When the bus-bar voltage exceeds
400V or falls to 50V or below during
compressor operating.

Communication error
between P.C. boards

Current sensor

Zero cross detecting circuit

Converter

Bus-bar voltage
(1)

Bus-bar voltage
(2)

w

Even if this protection stop is

performed continuously three
times, it does not mean the
abnormality in outdoor power
system.

Lighting 6 times

Lighting 7 times

5 times

Goes

out

5 times

Goes

out

5 times

6 times

Goes

out

Goes

out

Abnormal point

(Failure mode / protection)

Condition

Correspondence

Indoor/outdoor

unit failure mode

recall function

LED indication

(Outdoor P.C. board)

LED 1

LED 2

The left lamp of

OPERATION INDICATOR

lamp (Indoor unit)

NOTE : Blinking patterns of this mode differ from the ones of Troubleshooting check table (10-4.).

MUZ-GB50VA

OB455A--1qxq 06.7.31 2:19 PM Page 19