PERFORMANCE DATA HEAT operation
CAPACITY:5.8(kW)
INPUT:1700(W)
OUTDOOR WB(
:
)
INDOOR
-10
-5
0
5
10
15
20
DB(
:
)
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
21
26
3.65
1105
4.41
1326
5.16
1496
5.92
1615
6.67
1717
7.37
1768
8.12
1802
3.48
1190
4.18
1411
4.93
1564
5.63
1683
6.38
1768
7.08
1819
7.80
1887
3.13
1275
3.89
1496
4.58
1649
5.34
1768
6.09
1853
6.79
1904
7.54
1955
MSZ-GB50VA : MUZ-GB50VA
Rated frequency 75Hz
ACTUATOR CONTROL
9
MUZ-GB50VA
9-2. R.V. coil control
Heating . . . . . . . . . . . . . . . . ON
Cooling. . . . . . . . . . . . . . . . . OFF
Dry . . . . . . . . . . . . . . . . . . . . OFF
NOTE: The 4-way valve reverses for 5 seconds right before start-up of the compressor.
ON
OFF
ON
OFF
Outdoor fan
motor
Compressor
5 seconds
15 seconds
ON
OFF
Compressor
Outdoor fan
motor
ON
OFF
5 seconds
5 seconds
R.V.coil
ON
OFF
ON or OFF
ON or OFF
9-1. Outdoor fan motor control
The fan motor turns ON/OFF, interlocking with the compressor.
[ON] The fan motor turns ON 5 seconds before the compressor starts up.
[OFF] The fan motor turns OFF 15 seconds after the compressor has stopped running.
NOTE Q : Total capacity (kW) INPUT : Total power input (W) DB : Dry-bulb temperature WB : Wet-bulb temperature