Muz-gb50va – MITSUBISHI ELECTRIC MUZ-GB50VA User Manual

Page 18

background image

18

OFF

None (Normal)

2-time flash

3-time flash

4-time flash

5-time flash

6-time flash

7-time flash

8-time flash

Lighting Lighting

Lighting

Once

Lighting

Once

Lighting Twice

Lighting 3 times

Lighting 4 times

Lighting 9 times

Once

Goes

out

Lighting Lighting

Lighting Lighting

3 times

Goes

out

4 times

Goes

out

Lighting Lighting

Lighting Lighting

Lighting 5 times

9-time flash

10-time flash

• Check the connection

of the compressor
connecting wire.

• Refer to 10-6.

A

"How to check
inverter / compressor".
• Check the stop valve.

• Replace the outdoor
electronic control
P.C. board.

•Check refrigerant circuit
and refrigerant amount.
• Refer to 10-6.

G

"Check

of LEV".

• Refer to 10-6.

D

"Check

of outdoor fan motor".

• Replace the outdoor
electronic control
P.C. board.

•Check refrigerant circuit
and refrigerant amount.
• Refer to 10-6.

G

"Check

of LEV".

• Reconnect compressor
connector.
• Refer to 10-6.

A

"How to

check inverter/
compressor."
• Check the stop valve.

•Check refrigerant circuit
and refrigerant amount.
• Check the stop valve.

• Check around outdoor
unit.
• Check outdoor unit air
passage.
• Refer to 10-6.

D

"Check

of outdoor fan motor".

• Refer to 10-6.

B

"Check

of outdoor thermistors".

• Refer to 10-6.

B

"Check

of outdoor thermistors".

When over current protection stop is
continuously performed three times
within 1 minute after the compressor
gets started, or when converter
protection stop or bus-bar voltage
protection stop is continuously
performed three times within 3
minutes after start-up.

When thermistor shorts or opens
during compressor running.

When 28A current flow into intelligent
power module.

When the outdoor heat exchanger
temperature exceeds 70

:

during cooling or the indoor gas
pipe temperature exceeds 70

:

during heating.

When the fin temperature exceeds

87

:

during operation.

When the P.C. board temperature
exceeds 70

:

during operation.

When failure occurs continuously
three times within 30 seconds after
the fan gets started.

When nonvolatile memory data
cannot be read properly.

When the frequency of the
compressor is kept 80Hz or
more and the discharge
temperature is kept under 39

:

for more than 20

minutes.

Outdoor power system

Discharge temperature
thermistor

Defrost thermistor
Ambient temperature thermistor

Fin temperature thermistor

P.C. board temperature

thermistor

Outdoor heat exchanger
temperature thermistor

Over current

Discharge temperature

High pressure

Fin temperature

P.C. board temperature

Outdoor fan motor

Nonvolatile memory data

Discharge temperature

-

-

Abnormal point

(Failure mode / protection)

Condition

Correspondence

Indoor/outdoor

unit failure mode

recall function

LED indication

(Outdoor P.C. board)

LED 1

LED 2

When discharge temperature exceeds
116

°

C during operation.

Compressor can restart if discharge
temperature thermistor reads 100

:

or

less 3 minutes later.

The left lamp of

OPERATION INDICATOR

lamp (Indoor unit)

NOTE : Blinking patterns of this mode differ from the ones of Troubleshooting check table (10-4.).

MUZ-GB50VA

3. Outdoor unit failure mode table