beautypg.com

Monessen Hearth ILDV20PV User Manual

Page 6

background image

6

83D0511

ILDV20/ILDV30 Fireplace Insert

PRe-iNStALLAtiON iNFORMAtiON

ORiFice SiZeS, PReSSuReS AND Btus

NAtuRAL GAS

PROPANe GAS

Manifold Press: (w.c.)

3.5"

Manifold Press: (w.c.)

10"

Maximum Supply Pressure

10.5"

Maximum Supply Pressure

13"

Minimum Supply Pressure

4.5"

Minimum Supply Pressure

11"

BeFORe yOu StARt

Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all con-
tents for shipping damage and immediately inform your dealer if any damage is found. Do
not install any unit with damaged, incomplete, or substitute parts. Check your packing list to
verify that all listed parts have been received.

NOte: The ILDV Series fireplace inserts work without any electrical
supply. The blower must be attached to 110/10V AC.

Model Number

iLDV20NV

iLDV20PV

iLDV30NV

iLDV30PV

Gas Type

Natural

Propane

Natural

Propane

Max. BTU/hr Input

0,000

0,000

30,000

30,000

Min. BTU/hr Input

13,000

16,000

0,500

3,000

Orifice Size (as shipped)

#44

1.35 mm

#37

#51

hiGh eLeVAtiONS

Input ratings are shown in BTU per hour and are certified without deration for
elevations up to 4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, installation must be in accor-
dance with the current ANSI Z3.1/NFPA 54 and/or local codes having jurisdic-
tion.
In Canada, please consult provincial and/or local authorities having jurisdiction
for installation at elevations above 4,500 feet (1,370 m).