ILDV20/ILDV30 Fireplace Insert

AiR ShutteR ADjuStMeNt (NAtuRAL GAS ONLy)

ADjuSt the AiR ShutteR

The venturi of the burner is equipped with an air shutter. The opening of the venturi has been
set at 1/4" for Natural Gas and fully open for Propane installation at sea level. The burner on
Natural Gas models may be adjusted for high altitude as follows:

To increase air mixture, open the shutter more. This will reduce soot formation. Figure

32

To decrease air mixture, close the shutter. Flames will be more yellow. Figure 33

FP1940
air shutter part open

Air Shutter

FP1940

Figure 32
Push Adjustment Lip Up to Open Air Shutter

FP1941
air shutter fully open

Air Shutter

FP1941

Figure 33
Pull Adjustment Lip to Close Air Shutter