Warn ing – Monessen Hearth ILDV20PV User Manual
Page 11
83D0511
ILDV20/ILDV30 Fireplace Insert
11
iNStALLAtiON
ZeRO-cLeARANce (MetAL) FiRePLAce RequiReMeNtS
•
The damper and grate must be removed.
•
The smoke shelf, internal baffles, screen, refractory and metal or glass doors may be removed
(if applicable).
•
Do not remove or alter the insulation or any structured rigid frame members (metal sides, floor,
door frames, face of the fireplace, etc.).
W
ARN
iNG
•
installer must attach red warning plate to the inside of the firebox of fireplace
with screws supplied.
•
Do not cut any sheet metal parts of the fireplace in which this gas fireplace
insert is installed. thiS iS StRictLy PROhiBiteD!
•
if factory-built fireplace has no gas access hole(s) provided, drill a 1.5" (37.5
mm) or less through lower sides or bottom of firebox. you must plug the
access hole with noncombustible insulation after gas supply line has been
installed.
•
if your factory-built fireplace has air passages on the face for zero capabilities,
DO NOt BLOcK theSe PASSAGeS!
&P
ZERO
Insulation
Damper
Smoke
Shelf
Masonry Lining or Refractory
Screen
Metal or Glass Doors
Internal
Baf
fles
Masonry Lining or Refractory
Grate
Figure 5
Metal Fireplace Zero-Clearance Requirements
iMPORtANt: Please review the following carefully.
It is normal for inserts fabricated of steel to give off some expansion and/or contraction noises during
the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car
engine.
It is not unusual for your insert to give off some odor the first time it is burned. This is due to the curing
of the paint and any undetected oil from the manufacturing process.
Please ensure that your room is well ventilated. OPeN ALL WiNDOWS DuRiNG iNitiAL BuRN
OFF/cuRiNG PhASe.
Burn your insert for at least six (6) hours on "HIGH" the first time you use it. Place the fan in the "OFF"
position during this time.