Warn ing, Vent requirements – Monessen Hearth ILDV20PV User Manual
Page 13
83D0511
ILDV20/ILDV30 Fireplace Insert
13
VeNt iNStALLAtiON
W
ARN
iNG
•
Make sure the exhaust pipe on heater connects to exhaust
portion of cap. Attach flex liners. Figure 6
•
Do not crimp or rupture liner when bending it into chimney
offsets.
VeNt RequiReMeNtS
•
The exhaust vent must reline the entire length of chimney and terminate above chimney top.
•
Vent must meet all vent manufacturer's requirements when installed.
•
Make sure you have the following before installing unit:
•
3" and 3" UL 1777 Listed gas liner for air inlet and exhaust.
•
Vertical termination kit (AI31TK33A, HEDV3T81, HEDV3T11, HEDVRT)
FP1922
vent requirements
9/08
Maximum Height 40'
(1.9 m)
Minimum Height 10'
(3 m)
Exhaust
Inlet
Figure 6
Venting Unit
FP19