beautypg.com

Cdvsc7 & cdv7 series gas fireplace, Electrical installation c au ti on – Monessen Hearth CDVR33N/PV7;N/PE7;N/PSC7 User Manual

Page 38

background image

CDVSC7 & CDV7 Series Gas Fireplace

38

69D3011

To Junction Box
in Fireplace

Optional

AC Module

{

White

Black

Optional

Light

White

Black

{

Optional

Blower

White

Black

{

Optional

Aux.

Green

Plug in 

Connector

Connector Pin

To Control Board

Input 300 Watt Max. Each

Optional A/C Module Replaces 6V Adapter
When Used

6V AC
Adapter

Control Board

RF Receiver
ON/OFF Button

Pilot

Black / Thermopile

Red / Thermopile

Sensor

Ignitor / Sparker

Conversion
NG/LP

Plug-in Connector
Control Board to Command Center

OFF/LO

LED

ON/HI

Master Switch

Command Center

Optional

Wall Switch

Plug-in Connector
Stepper Motor to
Control Board

DC Power/Green

Ground

Plug-in Connector
Control Board to
Solenoid

Gas In

Gas Out

Pilot Gas Tubing

Valve

eleCTRICal InSTallaTIon

C

au

TI

on

electrical connections should only be
performed by a qualified, licensed electrician.
Main power supply must be turned off before
connecting fans to the main electrical power
supply or performing service.

Figure 56 -
Signature Command Wiring Diagram

noTe: Wall switch wires must be con-
nected together if a wall switch is not
being used.