CDVSC7 & CDV7 Series Gas Fireplace

69D3011

11

CleaRanCeS

CleaRanCeS To CoMBuSTIBleS

w

a

R

n

In

G

Follow these instructions carefully to
ensure safe installation. Failure to follow
instructions exactly can create a fire
hazard.
The appliance cannot be installed on a
carpet, tile or other combustible material
other than wood flooring. If installed on
carpet or vinyl flooring, the appliance
shall be installed on a metal, wood or
noncombustible material panel extending
full width and depth of the appliance.

72" 

Minimum

6”

Minimum

fP2032
wall clearances

Figure 5 -
Ceiling and Side Wall Clearances

FP03

Ceiling

Side
Wall

FP2285b
mantel clearances

W

X

Y

Z

A

B

C

D

Finish Wall

Header

Stud

Standoff

Top of Heat
Exhaust Vent

FP85b

CDV33/42/47
Side View

ManTel CleaRanCeS

noTe: The combustible area above the facing must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.

w

a

R

n

In

G

never obstruct or modify the air inlet or
outlet grilles (louvers). This may create
a fire hazard.

Figure 6 -
Mantel Clearances

Front View

6"

5"

3"

45°

1"

256O”

1

56O

3

56O

4

56O

FP2286
Mantel leg clear

Side of Fireplace
Opening

Stud

Wall

FP86

Combustible
Material Area

noTe: CDVR33SC7 has no standoffs.

FP2285 36
mantel clearances

12” (305 mm)

256O”

(64 mm)

13”

(330 mm)

12”

(305 mm)

Finish Wall

Header

Stud

Standoff

Top of Heat
Exhaust Vent

FP85

CDV36
Side View

Ref.

CDV33

CDV42/47 Ref.

CDV33

CDV42/47

A 14" (356 mm) 1" (305 mm) W 1" (305 mm) 1" (305 mm)
B 11" (79 mm) 9Z\x" (41 mm) X 8" (03 mm) 8" (03 mm)
C 10" (54 mm) 8Z\x" (16 mm) Y 6" (15 mm) 6" (15 mm)
D 8" (03 mm) 6" (15 mm)

Z Z\x" (64 mm) Z\x" (64 mm)