CDVSC7 & CDV7 Series Gas Fireplace
69D3011
11
CleaRanCeS
CleaRanCeS To CoMBuSTIBleS
w
a
R
n
In
G
Follow these instructions carefully to
ensure safe installation. Failure to follow
instructions exactly can create a fire
hazard.
The appliance cannot be installed on a
carpet, tile or other combustible material
other than wood flooring. If installed on
carpet or vinyl flooring, the appliance
shall be installed on a metal, wood or
noncombustible material panel extending
full width and depth of the appliance.
72"
Minimum
6”
Minimum
fP2032
wall clearances
Figure 5 -
Ceiling and Side Wall Clearances
FP03
Ceiling
Side
Wall
FP2285b
mantel clearances
W
X
Y
Z
A
B
C
D
Finish Wall
Header
Stud
Standoff
Top of Heat
Exhaust Vent
FP85b
CDV33/42/47
Side View
ManTel CleaRanCeS
noTe: The combustible area above the facing must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
w
a
R
n
In
G
never obstruct or modify the air inlet or
outlet grilles (louvers). This may create
a fire hazard.
Figure 6 -
Mantel Clearances
Front View
6"
5"
3"
45°
1"
256O”
1
56O
”
3
56O
”
4
56O
”
FP2286
Mantel leg clear
Side of Fireplace
Opening
Stud
Wall
FP86
Combustible
Material Area
noTe: CDVR33SC7 has no standoffs.
FP2285 36
mantel clearances
12” (305 mm)
256O”
(64 mm)
13”
(330 mm)
12”
(305 mm)
Finish Wall
Header
Stud
Standoff
Top of Heat
Exhaust Vent
FP85
CDV36
Side View
Ref.
CDV33
CDV42/47 Ref.
CDV33
CDV42/47
A 14" (356 mm) 1" (305 mm) W 1" (305 mm) 1" (305 mm)
B 11" (79 mm) 9Z\x" (41 mm) X 8" (03 mm) 8" (03 mm)
C 10" (54 mm) 8Z\x" (16 mm) Y 6" (15 mm) 6" (15 mm)
D 8" (03 mm) 6" (15 mm)
Z Z\x" (64 mm) Z\x" (64 mm)