beautypg.com

Installing rock wool and checking burner flame, Warning – Monessen Hearth Vent-Free Fireplace Systems DBX24C* User Manual

Page 27

background image

33D4047

27

INSTALLING ROCK WOOL AND CHECKING BURNER FLAME

PLACING ROCK WOOL

DFX24C AND DFX32C MODELS

After installing logs, pull apart dime-size pieces of rock wool. Sprinkle
rock wool evenly over burner ports. Wash hands after installing rock wool.
Itching may occur.

W

ARNING

• Use only rock wool provided with log set.

• Do not add additional rock wool.

• Place rock wool on burner ports only.

• Keep air gap between rear log and burner

CLEAN.

Figure 42 - Correct Appearance of Flames

(DFX24C)

Figure 40 - Rockwool Installation

(DFX24C and DFX32C)

One-piece

Log

Figure 41 - Correct Appearance of Flames

(DBX24C)

Dime Size

Rock Wool

CHECKING BURNER FLAME

DBX24C MODEL

In

normal operation at full rate after 15 minutes, the following

flame appearances should be observed:
The flames inside the one-piece log may be yellow. The
flames should extend approximately 2" - 4" above the log.
See Figure 41.

DFX24C AND DFX32C MODELS

In normal operation at full rate after 15 minutes, the following
flame appearances should be observed:
Burner will have a random pattern of yellow flames. See
Figures 42 and 43.
There should be glowing embers in front
of burner.

NOTE: The front flames and embers will be an
opaque orange color during the burn off time.

Figure 43 - Correct Appearance of Flames

(DFX32C)