beautypg.com

Emergencies, Troubleshooting – Meco BUSHMAN 7710S8.641 User Manual

Page 24

background image

Problem

Possible Cause

Solution

Gas leaking from
cracked/cut/burned
hose.

Damaged hose.

Mechanical failure due to rust
or mishandling.

Failure of valve from mishan-
dling or mechanical malfunc-
tion.

Fire in or around venturi tube
section of the burner.

Too much grease build-up in
burner section.

Replace LP Cylinder

Turn off LP cylinder valve. Return cylinder to gas supplier.

If you can safely reach the control panel, turn off control knobs
then close the LP cylinder valve. Once fire is out and grill has
cooled off. Remove burner(s) and inspect for blockage from spi-
der webs/nests or rust. See “How To Clean Burners.” section.
Replace any damaged parts.

Turn off control knobs and LP cylinder valve. Once fire is out
and grill has cooled off. Clean residual food particles and
excess grease from inside firebox area, grease cup and other
surfaces.

Emergencies

Turn off gas at the LP cylinder. Replace valve/hose/regulator
before continuing use.

Gas leaking from LP
cylinder

Gas leaking from LP
cylinder valve

Gas leaking between
LP cylinder and regu-
lator connection.

Fire coming through
control panel

Grease fire or exces-
sive flames above
cooking surface.

Improper installation, connec-
tion not tight, failure of seal
on LP cylinder valve.

Turn off LP Cylinder valve. Re-install correctly or tighten cou-
pling nut. Replace cylinder if seal is damaged. See “Leak Test
and “Connecting Regulator to LP Cylinder” sections.

Flashback....
(fire in or around ven-
turi tubes.

Clogged or blocked venturi
tube.

If you can safely reach the control panel, turn control knobs to
“OFF” then close LP cylinder valve. Clean burner and venturi
tubes.“See “How To Clean Burners” Section.

Regulator Coupling nut is not
fully connected to LP cylinder

Tighten coupling nut by hand about one-half to three quarters
additional turn. Do not use tools.

LP- gas cylinder is empty

Take LP gas cylinder to licensed LP gas supplier to be refilled.

No spark, electrode cracked,
broken or loose.

1-Make sure all the wires are connected and to the right

terminals.

2-If Electronic, check the battery. Make sure it is pushed in the

holder.

3-Gas collector tab is bent (making too large or small of a gap

between electrode and tab). By hand, bend gas collector tab
back within a maximum of 3/16” gap to electrode. (Page 26)

4-Tighten Electrode mounting screws.
5-Replace damaged electrodes.

Burners will not light
using the ignitor

Burners not assembled
correctly

See re-assembly after cleaning in Care and Maintenance.

Problem

Possible Cause

Solution

Troubleshooting

Not pausing long enough
before clicking the Ignitor
Button

When lighting the Burner, push-in and turn control panel knob
counter-clockwise to the high position. Pause 4 seconds, then
Push in Ignitor button several times so that it clicks each time.

24