MITSUBISHI ELECTRIC 9700 SERIES UPS

UF254

88C ABNORMAL

Fan power source abnormality during operation

1

[1]

Minor

Flicker

197

UF255

52C ABNORMAL

52C turned OFF during inverter power supply

1

[1]

Minor

Flicker

128

UF256

OUTPUT VOLTAGE

ABNORMAL

Inverter output voltage fell out of +/- 5%

1

[1]

Minor

Flicker

109

UF257

52C ABNORMAL

52C not turned OFF when manual transfer

1

[1]

Minor

Flicker

98

UF301

UPS CONTROL CIRCUIT

ERROR

Control microcomputer abnormality

1

[2]

Major

Lit up

19

UF302

UPS CONTROL CIRCUIT

ERROR

Control microcomputer abnormality

1

[2]

Major

Lit up

28

UF303

UPS CONTROL CIRCUIT

ERROR

Control microcomputer abnormality

1

[2]

Major

Lit up

29

UF304

UPS CONTROL CIRCUIT

ERROR

Control microcomputer abnormality

1

[2]

Major

Lit up

31

UF305

UPS CONTROL CIRCUIT

ERROR

Control circuit abnormality

1

[2]

Major

Lit up

21

UF306

UPS CONTROL CIRCUIT

ERROR

Control power source circuit abnormality

1

[2]

Major

Lit up

16

UF309

INVERTER VOLTAGE

ABNORMAL

Inverter output voltage abnormality before
inverter power supply

1

[2]

Major

Lit up

83

UF351

CONTROL FUSE BLOWN Battery circuit's fuse burnt

1

[1]

Minor

Flicker

115

UF352

SUPPLY OF CONTROL

CIRCUIT ABNORMAL

Control circuit abnormality

1

[1]

Minor

Flicker

111

UF355

(Note10)

UPS CONTROL CIRCUIT

ERROR

Control circuit abnormality

1

[1]

Minor

Flicker

130

UF356

UPS CONTROL CIRCUIT

ERROR

Control circuit abnormality

1

[1]

Minor

Flicker

123

UF357

"INVERTER START "

BUTTON ABNORMAL

"INVERTER START" button is abnormal (Local)

1

[1]

Minor

Flicker

124

UF358

"INVERTER STOP "

BUTTON ABNORMAL

"INVERTER STOP" button is abnormal (Local)

1

[1]

Minor

Flicker

125

UF359

"INVERTER SUPPLY"
BUTTON ABNORMAL

"INVERTER SUPPLY" button is abnormal

1

[1]

Minor

Flicker

126

UF360

"BYPASS SUPPLY"

BUTTON ABNORMAL

"BYPASS SUPPLY" button is abnormal

1

[1]

Minor

Flicker

127

UF362

UPS CONTROL CIRCUIT

ERROR

52S control circuit abnormality (Note 8)

1

[1]

Minor

Flicker

195

UF401

52S ABNORMAL

52S not turned ON, or 52S turned ON without
any command

1

[2]

Major

Lit up

84

UF402

52S ABNORMAL

52S not turned OFF, or 52S turned OFF without
any command

1

[2]

Major

Lit up

85

UF451

52S ABNORMAL

52S not turned ON, or 52S turned ON without
any command when manual transfer

1

[1]

Minor

Flicker

99

UA801

AC INPUT VOLTAGE OUT

OF RANGE

AC input voltage fell out of +/- 18% range

3

[1]

Note 5

239

UA802

AC INPUT FREQUENCY

OUT OF RANGE

Ac input frequency fell out of converter
synchronization follow-up range

3

[1]

Note 5

161

UA803

AC INPUT PHASE

ROTATION ERROR

Phase rotation is inverted when input voltage is
normal

3

[1]

Note 5

236

UA804

(Note10)

BATTERY ABNORMAL

Battery abnormal (External input)

1

[1]

Note 5

238

UA805

(Note10)

AMBIENT TEMPERATURE

ABNORMAL

Temp. abnormality in room where installed

11

[1]

237

UA806

INVERTER OVERLOAD >

100%

Overload exceeded 105% (Note 9)

4

[1]

Over

Flicker

216

UA807

INVERTER OVERLOAD >

110%

Overload exceeded 110% (Note 9)

4

[1]

Over

Flicker

217

UA808

INVERTER OVERLOAD >

125%

Overload exceeded 125% (Note 9)

4

[1]

Over

Flicker

218

UA809

INVERTER OVERLOAD >

150%

Overload exceeded 150% (Note 9)

4

[1]

Over

Flicker

219

UA810

OVERLOAD

Momentary over-current during Inverter power.

4

[1]

Over

Flicker

220

UA811

BYPASS VOLTAGE OUT

OF RANGE

Bypass voltage fell out of +/- 15% range at
manual transfer

5

[1]

Note 5

240